Hello guys!
You all have been very helpful in providing infos for my next build, a good old 4 CXB3590 3000K 90 CRI setup. Maybe i could have done my homework a little better, I've seen there are better cobs around, but the order has been placed and alas, this will do. However, I can't find the help i need for wiring a little LCD energy meter into my system, so that I can monitor the wattage of the cobs that I plan to regulate via an external linear 100k ohm potentiometer hooked to my HLG-185H-C1400B.
I've found two different kinds of LCD energy meters, one with model number PZEM-061 and the other, PZEM-051.
PZEM-061 is an AC energy meter, with a ring trough which i should thread either the line or the neutral coming from the wall and going to the driver.
PZEM-051 is a DC energy meter, that must be wired in series with the cobs by using a "shunt" (in quotes because it's not really clear to me what it is). Intuition tells me that this is the one i need, but... Current obviously flows trough this shunt, in series with the cobs, should i worry about it?
Which one is the right one? Does plugging an energy meter and a dimmer in the system "rob" the driver of current/voltage, thus preventing me from running 4 cobs @ 1.4 ampere? I tried to calculate everything, to be sure that I could power 4 CLX3590, 36V with the HLG-185H-C1400B, and the calculation came up pretty tight.
Thanks to everybody in advance!
You all have been very helpful in providing infos for my next build, a good old 4 CXB3590 3000K 90 CRI setup. Maybe i could have done my homework a little better, I've seen there are better cobs around, but the order has been placed and alas, this will do. However, I can't find the help i need for wiring a little LCD energy meter into my system, so that I can monitor the wattage of the cobs that I plan to regulate via an external linear 100k ohm potentiometer hooked to my HLG-185H-C1400B.
I've found two different kinds of LCD energy meters, one with model number PZEM-061 and the other, PZEM-051.
PZEM-061 is an AC energy meter, with a ring trough which i should thread either the line or the neutral coming from the wall and going to the driver.
PZEM-051 is a DC energy meter, that must be wired in series with the cobs by using a "shunt" (in quotes because it's not really clear to me what it is). Intuition tells me that this is the one i need, but... Current obviously flows trough this shunt, in series with the cobs, should i worry about it?
Which one is the right one? Does plugging an energy meter and a dimmer in the system "rob" the driver of current/voltage, thus preventing me from running 4 cobs @ 1.4 ampere? I tried to calculate everything, to be sure that I could power 4 CLX3590, 36V with the HLG-185H-C1400B, and the calculation came up pretty tight.
Thanks to everybody in advance!