VENTS pro tt 200 are they all mixed flow?

bandit08

Well-Known Member
Mine has only 1 live wire but on further inspection I've found another live wire turned back on its self and tucked away into the cables outer casing. Is this my low speed live? Its red
 

piratebug

Well-Known Member
Yeah, you will have (2) live wires, one is L1, the (low speed terminal), and the other is L2, the (high speed terminal) but you can only configure one them if you don't have a external speed switch. But if you do have a external speed switch, both L1 and L2 go to the dual ESS and the live lead on the on/off switch goes to in-line ESS connector. But you can also use a standard 3 way toggle switch instead of a ESS so you can have both low/high speeds available to you.
 

bandit08

Well-Known Member
Yeah, you will have (2) live wires, one is L1, the (low speed terminal), and the other is L2, the (high speed terminal) but you can only configure one them if you don't have a external speed switch. But if you do have a external speed switch, both L1 and L2 go to the dual ESS and the live lead on the on/off switch goes to in-line ESS connector. But you can also use a standard 3 way toggle switch instead of a ESS so you can have both low/high speeds available to you.
Thanks very much for clearing that up!! I dont have an external switch, I'm just going to swap the live over.
 
Top