Talk about EC

Widow Maker

Well-Known Member
Can someone give me a detailed explanation on how ec works and what to look for? Maybe rollitup can bust one of those articles out for me. Thanks in advance.
 

potroastV2

Well-Known Member
Total Dissolved Solids (TDS) is the best measurement of the nutrient concentration of a hydroponic solution. To estimate TDS, one can use a meter that measures the Electric Conductivity (EC) of a solution, and convert the number to TDS in parts per million (ppm). Many meters will do this conversion.

Total dissolved solids (TDS) is typically expressed in parts per million (ppm). It is a measurement of mass and determined by weighing, called a gravimetric analysis. A solution of nutrients dissolved in water at a strength of 700 ppm means that there are 700 milligrams if dissolved solids present for every liter of water. To accurately calculate total dissolved solids (TDS), one would evaporate a measured filtered sample to dryness, and weigh the residue. This type of measurement requires accurate liquid measurement, glassware, a drying oven, and a milligram balance. Example: 50 mL of the 700ppm solution would leave 35 mg of salt at the bottom of a crucible after drying.

Electrical Conductivity (EC) is expressed in siemens per centimeter (s/cm) or milliseimens per centimeter(ms/cm). It can be determined with an inexpensive hand held meter. Nutrient ions have an electrical charge, a whole number, usually a positive or negative 1, 2, or 3. EC is a measurement of all those charges in the solution that conduct electricity. The greater the quantity of nutrient ions in a solution, the more electricity that will be conducted by that solution. A material has a conductance of one siemens if one ampere of electric current can pass through it per volt of electric potential. It is the reciprocal of the ohm, the standard unit of electrical resistance. A siemens is also called a mho (ohm backwards).

For convenience, EC measurements often are converted to TDS units (ppm) by the meter.

The meter cannot directly measure TDS as described above, and instead uses a linear conversion factor to calculate it. Everyone’s nutrient mix is different, so no factor will be exact. The meter uses an approximate conversion factor, because the exact composition of the mix is not known. Conversion factors range from .50 to .72, *depending on the meter manufacturer, which do a good job of approximating a TDS calculation from the meter’s measurement of EC.

* All ppm pens actually measure the value based on EC and then convert the EC value to display the ppm value, having different conversion factors between differing manufacturers is why we have this problem communicating nutrient measurments between one another.

EC is measured in millisiemens per centimeter (ms/cm) or microsiemens per centimeter (us/cm).

One millisiemen = 1000 microsiemens.

EC and CF (Conductivity Factor) are easily converted between each other.
1 ms/cm = 10 CF

"The communication problem"...
So again, the problem is that different ppm pen manufacturers use different conversion factors to calculate the ppm they display. All ppm (TDS, Total Dissolved Solids) pens actually measure in EC or CF and run a conversion program to display the reading in ppm's.

There are three conversion factors which various manufacturers use for displaying ppm's...

USA 1 ms/cm (EC 1.0 or CF 10) = 500 ppm
European 1 ms/cm (EC 1.0 or CF 10) = 640 ppm
Australian 1 ms/cm (EC 1.0 or CF 10) = 700 ppm

For example,

Hanna, Milwaukee 1 ms/cm (EC 1.0 or CF 10) = 500 ppm
Eutech 1 ms/cm (EC 1.0 or CF 10) = 640 ppm
Truncheon 1 ms/cm (EC 1.0 or CF 10) = 700 ppm

Calculating the conversion factor

If your meter allows you to switch between EC and TDS units, your conversion factor can be easily determined by dividing one by the other.

Place the probe in the solution and read TDS in ppm. Change to EC on the meter and read EC in ms/cm.

Conversion factor = ppm / ec.

[Note: ms must be converted to us: One millisiemen = 1000 microsiemens (1.0 ms/cm = 1000.0 us/cm)

According to the chart below:
1.0 ms/cm = 500 ppm (USA Hanna)
1000 us/cm = 500 ppm

Conversion factor = ppm / (ms/cm * 1000)
.50 = 500ppm / (1000us/cm) ]

The answer is your meter's convertion factor and should be a number between 0.50 and 0.72 To improve accuracy, take ec and ppm readings from your res daily for about ten days. Average the conversion factors. The more data points that you use, the closer you will be to finding your true conversion factor.

When reporting your PPM in a thread, please give the conversion factor your meter uses. For example: 550 PPM @0.7 or give the reading in EC, which should be the same meter to meter.

It may also be advisable to give the starting value of your water; there is a huge difference between RO and distilled water with a PPM of approximately 0 and hard tap water of PPM 300 @.5 (notice the conversion factor so others can work out the EC) or well water with a conductance of 2.1 ms/cm.


A note to Organic Growers:
An EC meter has fewer applications for a soil grower because many organic nutrients are not electrically charged or are inert. Things like Superthrive or Fish Emulsion, blood meal, rock phosphate or green sand cannot be measured with a meter reliably when they are applied or in runoff. Meters can only measure electrically charged salts in solution.

"The solution"...
When reporting your PPM in a thread please give the conversion factor your meter uses for example 550 PPM @.7 or give the reading in EC (the EC shoul d be the same meter to meter).

EC Hanna Eutech Truncheon CF
ms/cm 0.5 ppm 0.64 ppm 0.70 ppm 0
0.1 50 ppm 64 ppm 70 ppm 1
0.2 100 ppm 128 ppm 140 ppm 2
0.3 150 ppm 192 ppm 210 ppm 3
0.4 200 ppm 256 ppm 280 ppm 4
0.5 250 ppm 320 ppm 350 ppm 5
0.6 300 ppm 384 ppm 420 ppm 6
0.7 350 ppm 448 ppm 490 ppm 7
0.8 400 ppm 512 ppm 560 ppm 8
0.9 450 ppm 576 ppm 630 ppm 9
1.0 500 ppm 640 ppm 700 ppm 10
1.1 550 ppm 704 ppm 770 ppm 11
1.2 600 ppm 768 ppm 840 ppm 12
1.3 650 ppm 832 ppm 910 ppm 13
 

kovo

Active Member
quick question i decided to buy an ec tester after hearing abit about it. after purchasing it and testing my water im not sure what reading i should be looking for i'm running my nutrients at half strength off the bottle which is around 2.5ml per litre. my ec tester reads 12 when i test my water is there a guage of wat an optimum level for your ec should be at? because at the moment i'm confused at wat i should be aiming for. any info would be great.
 

Chummy

Active Member
quick question i decided to buy an ec tester after hearing abit about it. after purchasing it and testing my water im not sure what reading i should be looking for i'm running my nutrients at half strength off the bottle which is around 2.5ml per litre. my ec tester reads 12 when i test my water is there a guage of wat an optimum level for your ec should be at? because at the moment i'm confused at wat i should be aiming for. any info would be great.
Starting at ec.- 1.0 for young seedlings going up to ec.-1.8 for large (4') plants.
Increase ec. by .2 per week until max is reached.
Do not confuse ec with cf. 1.0 ec would be equal to 12 cf.

This has worked well for me and I hope it helps you.

tokes2ya:)-Chummy
 

Kronic08

Active Member
My meter reads us/cm so what type is that cf or ec? also what would be the conversion formula to get a reading like 1.0??
 

aerofirst

Active Member
Late comer but I just took a reading on one of these http://www.tdsmeter.com/products/ec3.html (EC-3 meter) and the reading was 146 - and when I did a reading on my tap water it was 701 ... just wondering if I'm doing this wrong, as it is really confusing for me. The 146 reading is in my aero setup and they are 2 week old seedlings (which look like they arn't doing to well - the 1st true leaves curling under - any help would be really great. Thank you :)
 

jondamon

Well-Known Member
most nutrient manufacturers will have an EC level either on their bottles or in their feeding schedule .

for example i use IONIC nutes which say 7ml/L or EC1.5 if i wanted half strength i would use EC0.75


J
 

aerofirst

Active Member
I looked again and there is a x10 I was overlooking! So today's reading was 135x10 = 1350 for seedlings. Is this OK?

Also how does the EC3 reading of 1350 translate to PPM?

Thank you for your help :)
 