DemonTrich
Well-Known Member
ok, i turned on the lights in my veg tent this friday with my old CG's help. here is what i have working with to give you an idea of whats going on. the tents are in the basement. ambient basement temps are 66* +/-2*. basement intake and exhaust are pulled from ambient basement air. intake air is opposite side of tents than exhaust air. ive done 5hr test runs and stays stable at 77*. used another temp gauge and reads the same temp (eliminating a possible faulty temp gauge).
tent: 4x4x7 secret jardin dr120 (dark room version) w/white panda film floor (comes black from mfg)
600w apollo XL cool tube hood (dimmable, digital ballast) 100% power
vent tech 6" 440 cfm cfm fan pushing air over an XL a/c cool tube (duct/fan/duct/tent/duct/cool tube/duct/tent/duct) w/speed controller (full/100%)
6" 250cfm booster fan (fresh air inlet) lower hole enterance
8" 500 cfm booster fan (exhaust) roof hole exit
one 5" clip style fan inside tent (i have a 2nd, but need extension cord)
temp/humidity with high/low memory.
i have the hood fan on 100%, lights about 1.5-2' from temp/humidity monitor (monitor placed ditectly under hood/light). temp are stable at 77* +/-1*. humidity im not worried about yet as i have NO plants. still testing and dialing in. now if im hitting 77* w/o plants, once i add plants, my temps will raise correct? i have decent negative pressure in tent as well. im wondering if my current situation will be sufficient or do i need to change something up? im getting my clones next weekend, and want to be ready. this is the last thing i need to work on, besides the flower tent, which im still a ways away from running.
thanks guys
tent: 4x4x7 secret jardin dr120 (dark room version) w/white panda film floor (comes black from mfg)
600w apollo XL cool tube hood (dimmable, digital ballast) 100% power
vent tech 6" 440 cfm cfm fan pushing air over an XL a/c cool tube (duct/fan/duct/tent/duct/cool tube/duct/tent/duct) w/speed controller (full/100%)
6" 250cfm booster fan (fresh air inlet) lower hole enterance
8" 500 cfm booster fan (exhaust) roof hole exit
one 5" clip style fan inside tent (i have a 2nd, but need extension cord)
temp/humidity with high/low memory.
i have the hood fan on 100%, lights about 1.5-2' from temp/humidity monitor (monitor placed ditectly under hood/light). temp are stable at 77* +/-1*. humidity im not worried about yet as i have NO plants. still testing and dialing in. now if im hitting 77* w/o plants, once i add plants, my temps will raise correct? i have decent negative pressure in tent as well. im wondering if my current situation will be sufficient or do i need to change something up? im getting my clones next weekend, and want to be ready. this is the last thing i need to work on, besides the flower tent, which im still a ways away from running.
thanks guys