On the other hand THC boils at relatively low temperatures in a vacuum. See attached graph, compliments of Skyhighler:
I used to use -29.9" Hg, but have backed off to -29.5" Hg to preserve them. Anything in the micron range would require super chilling the THC to preserve it.
Maybe I asked it wrong, I've never seen a pump rated in the thousands. When muffing; and the vac is on and it's max pressure is 25 microns. Is't it going to go beyond the max pressure of -29 hg; even though it won't show it on the gauge?We only purge at -29.5 hg, which is about 319, 200 microns. At 25 microns, THC and the other terpenes are boiling at room temperature.
You may be looking at the number backwards and I seem to have lost my mind with that number.Maybe I asked it wrong, I've never seen a pump rated in the thousands. When muffing; and the vac is on and it's max pressure is 25 microns. Is't it going to go beyond the max pressure of -29 hg; even though it won't show it on the gauge?
Its this line of thinking that makes me reluctant to use a pump rated at 25 micron.
Oxidation smoxidation, that's the cause no? Aside from the fact didferent strains have different cannabinoid profiles?Airation=oxidation
Even a single stage pump will pull under 100 microns, so you have to bleed in air to keep it from pumping below 29.5" Hg.Am I getting this right now?
So a pump rated at 25 microns will always pull ultimate vacuum at about -29.9hg period?
Where you want no more than -29.5; a 10k micron rating to keep thc boiling above 160f?
Also how is a 10k pump rated on the box, can't seem to find any examples...
I just got one of these (7cfm)
http://www.yellowjacket.com/product/948
Beginning to think it's the reason for darker stuff we been getting.
I love you science; oh and you too fade.. lolEven a single stage pump will pull under 100 microns, so you have to bleed in air to keep it from pumping below 29.5" Hg.
As I understand it (from Fade mostly) the dark is from the temperature.Am I getting this right now?
So a pump rated at 25 microns will always pull ultimate vacuum at about -29.9hg period?
Where you want no more than -29.5; a 10k micron rating to keep thc boiling above 160f?
Also how is a 10k pump rated on the box, can't seem to find any examples...
I just got one of these (7cfm)
http://www.yellowjacket.com/product/948
Beginning to think it's the reason for darker stuff we been getting.
That will do you more that just fine. I have something very similar, the 6 cfm, 2 stage CPS. It probably could suck the chrome off a bumper.hey guys i have a robinair 15500 2 stage 5 cfm pump which is rated at 40-50 microns from what i can find online - is this adequate for purging my winterized bho or do i need lower micron?
I was wondering I'm here in New Hampshire not too far away from Canada although I do live in Southern New Hampshire I just ordered a 5 gallon 7CFM Purge system with a one stage pump 4 $200 on Amazon I am a complete newbie and I would appreciate any of some of the great advice that I have been reading I f****** love this thread everyone is so chill no one is a douchebag I think everyone understands that some people have a lot more knowledge than others and they are actually willing to share and spoon feed this information two people like myself who don't know where to find such informative answers thank you everyone cheers and happy holidaysyeah ordering online is the best thing ive ever done... and worst thing on my bank account. need something? anything, some random crazy weird piece.. find it in 2 minutes, pay tonight and have it shipped in the morning, providing shipping isnt a deal breaker, and you can afford to wait a week or so. I love it!!!! especially being in canada... your guys' prices in the states are fucking lowww!!! like 40% off everything, or more.