Isn't that for each holder, not a series rating....I gotta look too, I run them in a series, lower voltage though, so I haven't worried about it....interesting......I'm interested in doing a flowering setup with 24 3000k 3070 ab's at 350mAh. I'm thinking a 3x3 area which puts it at about 15 par/sq ft. I wanted to use the 50-2234C ideal holders, but they're only rated to 250v/4amps. I'd like to use two HLG-120H-C350 to power 12 each, but if I'm to obey the ideal holder specs I must sacrifice a good deal of efficiency by splitting it into 3 or 4 smaller power supplies. At that point it'd be pointless and I might as well rethink it as a 500 or 700 mah unit.
Can the ideal holders withstand more than their specs let on at lower temps? They're rated to 110 C and I won't be anywhere near that. Probably wishful thinking. Should I just suck it up and abandon the handy holders?