Ohms Law ??? Can 62vdc become 145vdc ???

BST

Active Member
I have a lpc 150-2450(31~62vdc) if ran parallel string of 4 lines @ 612.5 ma. Do you get 245vdc?
 

Isawthelight

Well-Known Member
I have a lpc 150-2450(31~62vdc) if ran parallel string of 4 lines @ 612.5 ma. Do you get 245vdc?
Your four parallel strings will measure no more than 62 vdc. BTW if only one diode or wire in a string breaks, the other three strings will carry 816 ma. Can your diodes carry this extra current?
 

BST

Active Member
Your four parallel strings will measure no more than 62 vdc. BTW if only one diode or wire in a string breaks, the other three strings will carry 816 ma. Can your diodes carry this extra current?
So how many fv can each string handle? I ducked up and ordered a 2450 instead of 1400ma? To little time to much kush. I'm going to have order a cob to match. Any ideas?
 

BST

Active Member
Parallel. I think I'm going to try to get as close to 150w and see what happens to a single
 

Isawthelight

Well-Known Member
Parallel. I think I'm going to try to get as close to 150w and see what happens to a single
3 vero 29 in parallel = 38.9 Vf (max) x 2.45 Amps = 94.57 watts. Putting more Vero 29 in parallel will not increase the watts to the plants but this will make each cob operate at a lower and more efficient temperature.
 
Last edited:

BST

Active Member
3 vero 29 in parallel = 38.9 Vf (max) x 2.45 Amps = 94.57 watts. Putting more Vero 29 in parallel will not increase the watts to the plants but this will make each cob operate at a lower and more efficient temperature.
Yes but a lpc150-2450 is a cc driver. If a Vero 29 has 39Vf can ya run 3 on it. Lpc150-2450 vdc is 31~62. Does vdc stay the same???
 
Top