I'm running a hlg-320h-c1050a the voltage range is 152-305. I'm planning on running 5 clu058 1812's their voltage per the data sheet is min 47.8 typ 52 max 56.2. I'm still new to all of this so I want to understand it as much as possible. So if u go by the cob having a 52v I'll be at 260v which falls in that range. Does that mean that the driver is only going to supply only what the cobs needs. I just want to make sure because If u divide the drivers max voltage @305 by 5 that will be 61v which is over the max voltage of the COB. Also say I wanted to run 6 using the drivers max v that will give me 50.8v which is within the COBs range will this work. Driver output is 320.25watts. So 50.8 x 1.05 = 53.375watts x 6 COBs gives me 320.25 watts. So what I want to know is is 5 safe to run as long as it falls in the drivers range and would it be possible to run 6. I just want to make sure I'm looking at this correctly. Appreciate any help Thanx