Justin Freidman
Well-Known Member
At last it's ready....
I'm running 2 x 600W Metal Halide (will change to HPS for flower) and 1 x 300W CFL Maxibright 6400k (will change to 2700k for flower) with a 6-pot Alien XL flood and drain system.
I have a 24,000 BTU aircon to keep the temperature and humidity right. 3 exhaust fans - but just running one.
I ran into a slight issue using MH/HPS - the power where I live in shit, we have outages about once a week. So we installed a 30KVA auto-start generator. The only issue is it takes 5 seconds to kick in - so the lights go off due to re-strike time. Luckily the Lumatek ballasts deal with this and won't fire up the lights until a certain amount of time has past, and until they're ready again - so won't damage them.
Anyway, I installed a 3000VA APC UPS, but that isn't enough to run the MH/HPS lights for more than 5 seconds, they simply draw too much power when they come back on, even for that crazy size UPS. The only thing I could do is install the 300W CFL which run fine on the UPS. It means the plants won't have any light black out during critical times.
I run a security cam with movement detection setup to email me pictures of any movement to my phone and SMS also. So if I ever get picture of the police in there, it's time to make a run for it..
My seedlings are a week old now, so will move to this room and in to the flood and drain in another two weeks.
I can't wait to see how they do with 1500W of light.
Hope you like the pics,
J.

I'm running 2 x 600W Metal Halide (will change to HPS for flower) and 1 x 300W CFL Maxibright 6400k (will change to 2700k for flower) with a 6-pot Alien XL flood and drain system.
I have a 24,000 BTU aircon to keep the temperature and humidity right. 3 exhaust fans - but just running one.
I ran into a slight issue using MH/HPS - the power where I live in shit, we have outages about once a week. So we installed a 30KVA auto-start generator. The only issue is it takes 5 seconds to kick in - so the lights go off due to re-strike time. Luckily the Lumatek ballasts deal with this and won't fire up the lights until a certain amount of time has past, and until they're ready again - so won't damage them.
Anyway, I installed a 3000VA APC UPS, but that isn't enough to run the MH/HPS lights for more than 5 seconds, they simply draw too much power when they come back on, even for that crazy size UPS. The only thing I could do is install the 300W CFL which run fine on the UPS. It means the plants won't have any light black out during critical times.
I run a security cam with movement detection setup to email me pictures of any movement to my phone and SMS also. So if I ever get picture of the police in there, it's time to make a run for it..
My seedlings are a week old now, so will move to this room and in to the flood and drain in another two weeks.
I can't wait to see how they do with 1500W of light.
Hope you like the pics,
J.




Attachments
-
384.4 KB Views: 0