Grow Room Floorplans. Here to help.

potroastV2

Well-Known Member
heehee, I've been growing pot since your mom was a girl.

I also love it when you quote me twice.

Rave on, young man! Like I said, our members love the entertainment.


:mrgreen:
 

nuglets

New Member
heehee, I've been growing pot since your mom was a girl.

I also love it when you quote me twice.

Rave on, young man! Like I said, our members love the entertainment.


:mrgreen:
lmao...that's why you believe you can scrog 20 plants under a 4x6 screen? everyone disagreed with you and then you got mad and suspended me for 3 days. that is pathetic. on top of that you have threatened me, posted nasty comments about me on my rep wall, and accused me of being about 15 different members. the whole; i am this person or i am that person is getting old. i understand you though it may help add validity to your argument but now it just makes you look weak. you guys even shut down the thread in toke and talk just cause it had to do with phillipchristian cause a guy thanked him for getting him some free shit from his distributor. i find you comical and pathetic at the same time. unless you are 115 years old i doubt you have been growing since my mom was a girl. why not go back to the thread you started about me in the staff section and rant some more over there to those drinking your koolaid. or you could explain to people why it is you removed 2100 rep points from my account...were you upset with some of my comments? did the truth hurt? you just make too easy.
 

TheGreenHornet

Well-Known Member
Hey Phillip! I hope this post finds you well.. I see you have switched to 'invisible' mode.. probably for the best but now I can't PM you anymore - add me to friends immediately!

I have been thinking quite a bit on your advice for redoing my ventilation, and you might have something there.. At the moment, however, I have just found a property that looks fairly suitable for my future garden and wanted some clarification on whether or not this breaker box looks worthy of my 3,600 watt gameplan. (+ miscellaneous fans & whatnot)

The Electric 5108.jpg

get back to me when you get a moment, and as always thanks for the help

-tgh
 

phxrocks

Active Member
Sounds like you are going to need a good ac unit.
Minimum 12000 btu for a room that size.
If you have 2 inline fans, You can run 1 fan through your lights, and use another fan on to of a carbon filter standing upright.
The 1st fan will be strong enough to pull cool air through both lights, and you are filtering/recirculating the air inside the room with the 2nd.
I would set it up as sealed of a room as possible. Then you can think about some CO2 if you don't already have some.
Hey wondering if ya could help me out a little bit more. My last question had to do with humidity and now that I have gotten that under controlled I'm tackling the temp problems. My set up..
is a two tent (4x8) with two 600s in each tent. I'm using cool tubes with bat wings attached to them, that I purchased from htg. with the two lights going at 50 % in the one tent and the other lights completely off no intake fan on the temps were 110 when i got there today!!! I don't have the inline fans hooked up yet since I'm messing with wiring at the moment but I will be finished with that tomorow.
So after all the ranting I guess my question is gonna be... how the hell am I gonna cool this. My exhaust setup was gonna be a 450 cfm inline pulling through a carbon filter and through both lights exhausted outside Im not sure how much this will help with the temps, I'm guessing quite alot but I think I'm going to have to buy an ac unit. The room that the tents are in is about 300 sq ft at the most. So what size ac should I buy and do you think i should have a separate exhaust fan hooked up to my lights then the filter? Sorry about all the questions also and thanks ahead of time!!!
 

kamie

Active Member
hey guys im upgrading my tent to a 4x8. Think i can get by with my old 6 in can 33 filter and ducting it through 2 blockbusters with 600w bulbs using a 6 in max fan?
 

SimonD

Well-Known Member
hey guys im upgrading my tent to a 4x8. Think i can get by with my old 6 in can 33 filter and ducting it through 2 blockbusters with 600w bulbs using a 6 in max fan?
I'd strongly suggest upgrading to a Can50 or a Can66. Personally, I'd run a Can75. Why? Because I've done what you have planned. Good luck.

Simon
 

ScoobyDoobyDoo

Well-Known Member
the 33 is rated for 400cfm and the room is about 200cfm. the 6" max fan does like 250cfm. that is plenty to scrub the air in your room before you exhaust it. just my opinion.
 

Warlock1369

Well-Known Member
hey guys im upgrading my tent to a 4x8. Think i can get by with my old 6 in can 33 filter and ducting it through 2 blockbusters with 600w bulbs using a 6 in max fan?
Think you will be fine like that. But would like to sugest upgrading to a higher cfm fan and a bigger filter. Not for the scrubbing but for larger air flow. The more and faster you can move air thru your lights the cool they will be. And what you have sounds like alot of restriction. But like I said think it will work.
 

SimonD

Well-Known Member
Think you will be fine like that. But would like to sugest upgrading to a higher cfm fan and a bigger filter. Not for the scrubbing but for larger air flow. The more and faster you can move air thru your lights the cool they will be. And what you have sounds like alot of restriction. But like I said think it will work.
Yes. In a setup such as the OP's, the filter almost always acts as the bottleneck. FWIW my veg room, similarly configured with 2x600HPS', runs 3-4F above ambient. In terms of odor control, depends on one's propensity to put his freedom on the line for a $200 filter. You'll have to excuse me on this one.

Simon
 

ScoobyDoobyDoo

Well-Known Member
Yes. In a setup such as the OP's, the filter almost always acts as the bottleneck. FWIW my veg room, similarly configured with 2x600HPS', runs 3-4F above ambient. In terms of odor control, depends on one's propensity to put his freedom on the line for a $200 filter. You'll have to excuse me on this one.

Simon
i think the difference is that kamie is in a tent and you are in a room. tents are much easier to filter air in. i run a CAN33 in both of my 4x8 flower tents and it's just fine. no odor whatsoever in my lung room.
 

Warlock1369

Well-Known Member
Just because someone has a different opinion then you your just gonna get pissed and start shit? That's childish. And even if someone never grew but knows what there talking about and answers the question right what's wrong with that? Not saying scooby hasn't grown. I don't know. But he is on point with what he says. Hell for that matter how do we know you grow? How do we know I grow? Grow photos are everywhere online.
 
Top