On the other hand THC boils at relatively low temperatures in a vacuum. See attached graph, compliments of Skyhighler:Hint: lower micro rating = better purge
If you can get one in the 10-15 range you'll be set.
That is also a good point. However 29.5 isn't going to give you a complete purge, you're still going to have to use heat where you're going to lose some anyways. Tuff call...On the other hand THC boils at relatively low temperatures in a vacuum. See attached graph, compliments of Skyhighler:
I used to use -29.9" Hg, but have backed off to -29.5" Hg to preserve them. Anything in the micron range would require super chilling the THC to preserve it.
Why won't -29.5" Hg completely purge the oil at 115F? Ours has no detectable solvent and smells like the material it was extracted for.That is also a good point. However 29.5 isn't going to give you a complete purge, you're still going to have to use heat where you're going to lose some anyways. Tuff call...
Robinair makes a decent pump and 8cfm is certainly a handy size. You don't need a two stage, but it will work fine. We use a Robinair 15500 5 cfm two stage for some of our stuff.Thanks homie! What do u think of this one?
http://www.amazon.com/gp/aw/d/B001P7C7QM/ref=ox_sc_sfl_image_3?ie=UTF8&m=ATVPDKIKX0DER
Vac oven?Why won't -29.5" Hg completely purge the oil at 115F? Ours has no detectable solvent and smells like the material it was extracted for.
Our vacuum purges leave more flora flavor than purging by just heat used to do. The oil that we fully purge and decarboxylate using only heat, mostly has a hashy flavor.Vac oven?
I don't have an oven. I purge, then heat usually for several hours.
IDK. I think you have a good point though. Seems like you'd pull terpenes at 30. But am I pulling more by heating?
Yes, it would. Buy a good American made 7-8cfm for that much. Try Amazon or Ebay for JB or Yellow Jacket. Get one that is easy to change the oil!would a 14cfm Lab grade pump be overkill?
http://www.pchemlabs.com/product.asp?pid=3926
found one for 500 used. Would this be doing too much?
14cfm, two stage, and $500 are all three overkill for the purpose.would a 14cfm Lab grade pump be overkill?
http://www.pchemlabs.com/product.asp?pid=3926
found one for 500 used. Would this be doing too much?