Hi ALL,
I seem to be having problems with heat and trying to cool the tent down. I've listed the specs below for reference, but i can't see why i have heat issues ?
** Spec **
Tent - 160cm(L)x80cm(D)x160cm(H)
Fans - 2 x 6" 1000m³/h Box Fans (Intake - From almost outside cold feed in (CF attached) to FAN, then to Y-Piece to air feed to tent, and start of Lights / Exhaust - From End of Lights to Y-Piece, which also gets a feed from the CF in the tent)
LIGHTS: 2 x 600w (HPS) Digital Ballasts with Aerowing Air Cooled Reflectors on 12/12 - Lights are linked together via 6" ducting.
CONTROL: SMS 14amp Twin Controller. Idle @ 60%/Max Temp @ 24c set to AUTO
So that's the setup as it stands, I did a test with the temp gauges i have, with temps outside being at 2c, at the entrance of the INTAKE fan i placed a temp probe that measured at 11.8c, as i mentioned the CF is almost outside, then i put a temp probe at the exit of the cold feed in the tent (Lights OFF), and it was at 16.7c(don't ask were 5c came from, but god knows), and when the lights were ON and have been at 100% (600W) each for a few hours the temps at mid bush height was 27c !!!!
So as you can see i have heat gremlins, and can't find or catch the little sh*ts !
If anyone has a solution or an idea that would be great, as it's getting on my nerves, or even a redesign if needed.
Thanks
I seem to be having problems with heat and trying to cool the tent down. I've listed the specs below for reference, but i can't see why i have heat issues ?
** Spec **
Tent - 160cm(L)x80cm(D)x160cm(H)
Fans - 2 x 6" 1000m³/h Box Fans (Intake - From almost outside cold feed in (CF attached) to FAN, then to Y-Piece to air feed to tent, and start of Lights / Exhaust - From End of Lights to Y-Piece, which also gets a feed from the CF in the tent)
LIGHTS: 2 x 600w (HPS) Digital Ballasts with Aerowing Air Cooled Reflectors on 12/12 - Lights are linked together via 6" ducting.
CONTROL: SMS 14amp Twin Controller. Idle @ 60%/Max Temp @ 24c set to AUTO
So that's the setup as it stands, I did a test with the temp gauges i have, with temps outside being at 2c, at the entrance of the INTAKE fan i placed a temp probe that measured at 11.8c, as i mentioned the CF is almost outside, then i put a temp probe at the exit of the cold feed in the tent (Lights OFF), and it was at 16.7c(don't ask were 5c came from, but god knows), and when the lights were ON and have been at 100% (600W) each for a few hours the temps at mid bush height was 27c !!!!
So as you can see i have heat gremlins, and can't find or catch the little sh*ts !
If anyone has a solution or an idea that would be great, as it's getting on my nerves, or even a redesign if needed.
Thanks