[tl;dr] Uniseal is leaking. .. [End td;dr].
Finally got my RDWC put together!
20Gal Rubbermaid Brute (x4) + 40Gal Rubbermaid Brute (x1 - Res).
4" PVC connecting each Brute
4" Reduced to 1" Pipe > 1" Pipe into Pump. > 1/2" Pipe from top of pump into top of Res.
Used a hole saw and did pretty smooth holes in the Brutes. Uses a razor blade and smoothed the burred/rough edges (making sure not to remove too much plastic and only the extra specs pointing out).
Used a "goo" based spray as lube and grinded down the edges of the pvc to help insert.
There are no bends or turns in the system. All the containers are in a straight line.
The floor is flat. All the containers are on the same level.
Water Check 1: Filled a few inches above the top of the unseals. Everything is perfect!
Water Check 2: Filled to where I would keep the water-line (just below net pot). Two of my Unseals are leaking! Did some adjusting... now..
..one is a very minor leak , like a drip... it drops to the floor, then another drop leaks out after a second.
..the other uniseal is leaking at a fair bit faster pace, drop-drop-drop-drop.. but not quite a river thankfully. There was still a fair bit of water pooling on the floor..
I feel like the Brute bows very slightly when full, compared to when empty and this might be causing a problem?
At this point, I'm hoping I can find some kind of outdoor water sealant/silicon that I can apply to the uniseals. If not I'm out a fair bit of $ and need new/better containers and maybe bulkheads instead of uniseals?
I am open to any suggestions! <3
Finally got my RDWC put together!
20Gal Rubbermaid Brute (x4) + 40Gal Rubbermaid Brute (x1 - Res).
4" PVC connecting each Brute
4" Reduced to 1" Pipe > 1" Pipe into Pump. > 1/2" Pipe from top of pump into top of Res.
Used a hole saw and did pretty smooth holes in the Brutes. Uses a razor blade and smoothed the burred/rough edges (making sure not to remove too much plastic and only the extra specs pointing out).
Used a "goo" based spray as lube and grinded down the edges of the pvc to help insert.
There are no bends or turns in the system. All the containers are in a straight line.
The floor is flat. All the containers are on the same level.
Water Check 1: Filled a few inches above the top of the unseals. Everything is perfect!
Water Check 2: Filled to where I would keep the water-line (just below net pot). Two of my Unseals are leaking! Did some adjusting... now..
..one is a very minor leak , like a drip... it drops to the floor, then another drop leaks out after a second.
..the other uniseal is leaking at a fair bit faster pace, drop-drop-drop-drop.. but not quite a river thankfully. There was still a fair bit of water pooling on the floor..
I feel like the Brute bows very slightly when full, compared to when empty and this might be causing a problem?
At this point, I'm hoping I can find some kind of outdoor water sealant/silicon that I can apply to the uniseals. If not I'm out a fair bit of $ and need new/better containers and maybe bulkheads instead of uniseals?
I am open to any suggestions! <3