SHOSHON3N8TV

Active Member
Using the 'ole electrolysis method, I am going to separate hydrogen from oxygen using my hydrogen generator - then inject it with an airstone. This will essentially oxygenate the water in the aerogarden, but i wonder what the hydrogen will do. :roll: And yes it's getting exhausted out, no BOOM unless the hydrogen is stored.:dunce: Approximately 5 gallons per hour of HYDROGEN - H H O from distilled water is gonna get injected - anyone ever heard or tried this? Or am I just soooopa blaz3d lol?:eyesmoke:
 

CAN MAN

Member
Using the 'ole electrolysis method, I am going to separate hydrogen from oxygen using my hydrogen generator - then inject it with an airstone. This will essentially oxygenate the water in the aerogarden, but i wonder what the hydrogen will do. :roll: And yes it's getting exhausted out, no BOOM unless the hydrogen is stored.:dunce: Approximately 5 gallons per hour of HYDROGEN - H H O from distilled water is gonna get injected - anyone ever heard or tried this? Or am I just soooopa blaz3d lol?:eyesmoke:
it's going to cost $$ for the power . i hope you don't kill your self
 

SHOSHON3N8TV

Active Member
Not 2 much really for the power, I can run the hydrogen generator off of a BK power box running @ 30 amps. I work for a hydrogen company part-time - so I know thing or two about not blowing myself up...hehe.
 

txhomegrown

Well-Known Member
I cant seem to find any info about extra hydrogen and plants. As far as that goes, in all the years that I have been growing, both pot and more legal plants, I have never heard or read anything pertaining to this. Have you done any research? I have heard of using hydrogen peroxide in hydro units, but I have no idea if that is that same thing you are talking about doing. It doesnt seem that just blowing hydrogen into the water would change the moleculer structure of the water. But what the fuck do I know.
 

SHOSHON3N8TV

Active Member
I cant seem to find any info about extra hydrogen and plants. As far as that goes, in all the years that I have been growing, both pot and more legal plants, I have never heard or read anything pertaining to this. Have you done any research? I have heard of using hydrogen peroxide in hydro units, but I have no idea if that is that same thing you are talking about doing. It doesnt seem that just blowing hydrogen into the water would change the moleculer structure of the water. But what the fuck do I know.
I couldn't find anything either - just hyd.peroxide as you stated...that's why I want to test it out, i know for sure oxygenated h20 will help, not sure what the pure hydrogen bubbling up will do....hmmmm. Hope my blunt doesn't xplode...lol, I do wonder tho. :fire:
 

tea tree

Well-Known Member
nah he is right. they now sell these machines for hydro and they are pretty expensive I think but the latest thing. Some other forum every one bought one. The commercial machine lets you dila in how much oxygen I think. The hydrogen just offgasses harmlessly I read. Lots of o2. Very cool. Awesome.
 

CAN MAN

Member
I cant seem to find any info about extra hydrogen and plants. As far as that goes, in all the years that I have been growing, both pot and more legal plants, I have never heard or read anything pertaining to this. Have you done any research? I have heard of using hydrogen peroxide in hydro units, but I have no idea if that is that same thing you are talking about doing. It doesnt seem that just blowing hydrogen into the water would change the moleculer structure of the water. But what the fuck do I know.
bongsmilie hydrogen peroxide is h2o2 the extra oxygen molecule strips off in the water an is good for the root system but the hydrogen should evaporate it would take more electric current to bond them together
 

SHOSHON3N8TV

Active Member
Can you send me a link tea tree? I can up the amps all the way up to 60 amps if I want, making 10 Gallons per Hour, as a result producing more 0's from the separation of H H O (h20)...oxygenating the water even more!:leaf: And there is nothing on the net because hydrogen doesn't occur naturally...it's odorless and colorless; but I will post a video where I capture it in soap bubbles and detonate the hydrogen generated from pure water...it's on now. Thinkin about gettin another aerogarden to do side-by-side comparisons with an auto-flowerin'strain.:eyesmoke:
 

SHOSHON3N8TV

Active Member
He is talking about injecting pure hydrogen, NOT oxygen.
Actually when the h20 (2 parts hydrogen and 1 part oxygen) is separated i am injecting 2/3's hydrogen and 1/3 oxygen, and by controlling the amps I can inject alot of O's if I want. Hella oxygenated H20 as a result...according to TEA the hydrogen dissapates harmlessly with propa ventalation. :leaf:
 

CAN MAN

Member
bongsmilie hydrogen peroxide is h2o2 the extra oxygen molecule strips off in the water an is good for the root system but the hydrogen should evaporate it would take more electric current to bond them together
injection hydrogen mite make hydrogen sulfide you know the rotten egg smell if so it will change your water chemistry like ph drop or killing off good bacteria..soo keep an eye or in this case your nose on it good luckbongsmilie
 

Buddreams

Active Member
i still do not see the point of injecting hydrogen. Why not just get an o2 bottle and inject that to ur air stone.
 

CAN MAN

Member
anything over 19%to21% is oxygen rich an is bad like your cigarette could explode or thing like oil or greases could ignite
 

tea tree

Well-Known Member
he is not injecting anything lol dudes. He is using electrolysis, two metal plates or graphite are attached to a power source and when the power is turned on diferent molecules head to diferent poles due to SCIENCE and shit happens and I am real tired but oxygen and hydrogen are the byproduct. Oxygen stays and hydrogen leaves. Very fast very long term full proof powerful. No air pump is better we all agree. I have a 20 want and want bigger and I need a sheet of soundbourd now.
 

tea tree

Well-Known Member
could not find the machine but a member here has got one I know prob in UK.

I foudn this.

Abstract:


An oxygen emitter which is an electrolytic cell is disclosed. When the anode and cathode are separated by a critical distance, very small microbubbles and nanobubbles of oxygen are generated. The very small oxygen bubbles remain in suspension, forming a solution supersaturated in oxygen. A flow-through model for oxygenating flowing water is disclosed. The use of supersaturated water for enhancing the growth of plants is disclosed. Methods for applying supersaturated water to plants manually, by drip irrigation or in hydroponic culture are described. The treatment of waste water by raising the dissolved oxygen with the use of an oxygen emitter is disclosed.
Claims:


1. A dissolved oxygen generating device comprising:an oxygen emitter having an anode and a cathode separated at a critical distance, the critical distance ranging from 0.005 inches to 0.140 inches;a direct current source; anda control circuit including a thermistor temperature sensor and a timer control circuit, wherein a water temperature measured by the thermistor temperature sensor adjusts an off time of the timer control circuit.

2. The dissolved oxygen generating device of claim 1, further comprising:a water container holding a volume of water, the oxygen emitter placed within said water container and the thermistor temperature sensor measuring the water temperature within the water container.

3. The dissolved oxygen generating device of claim 2, wherein the off time of the timer control circuit is greater for cold water than compared to warm water.

4. The dissolved oxygen generating device of claim 1, wherein the critical distance is defined by a non-compressible, non-conducting spacer.

5. The dissolved oxygen generating device of claim 1, wherein the emitter comprises a multi-layer arrangement including at least one anode and at least two cathodes.

6. The dissolved oxygen generating device of claim 5, wherein the emitter comprises a plurality of anodes and a plurality of cathodes.
Description:


[SIZE=+1]RELATED APPLICATIONS[/SIZE]

[0001]This application is a continuation of application Ser. No. 10/732,326 filed Dec. 10, 2003, which in turn is a continuation-in-part of application Ser. No. 10/372,017, filed Feb. 21, 2003, now U.S. Pat. No. 6,689,262, which claims the benefit of U.S. Provisional Application No. 60/358,534, filed Feb. 22, 2002, each of which is hereby fully incorporated herein by reference.

[SIZE=+1]FIELD OF THE INVENTION[/SIZE]

[0002]This invention relates to the electrolytic generation of microbubbles of oxygen for increasing the oxygen content of flowing water. This invention also relates to the use of superoxygenated water to enhance the growth and yield of plants. The flow-through model is useful for oxygenating water for hydroponic plant culture, drip irrigation and waste water treatment.

[SIZE=+1]BACKGROUND OF THE INVENTION[/SIZE]

[0003]Many benefits may be obtained through raising the oxygen content of aqueous media. Efforts have been made to achieve higher saturated or supersaturated oxygen levels for applications such as the improvement of water quality in ponds, lakes, marshes and reservoirs, the detoxification of contaminated water, culture of fish, shrimp and other aquatic animals, biological culture and hydroponic culture. For example, fish held in a limited environment such as an aquarium, a bait bucket or a live hold tank may quickly use up the dissolved oxygen in the course of normal respiration and are then subject to hypoxic stress, which can lead to death. A similar effect is seen in cell cultures, where the respiring cells would benefit from higher oxygen content of the medium. Organic pollutants from agricultural, municipal and industrial facilities spread through the ground and surface water and adversely affect life forms. Many pollutants are toxic, carcinogenic or mutagenic. Decomposition of these pollutants is facilitated by oxygen, both by direct chemical detoxifying reactions or by stimulating the growth of detoxifying microflora. Contaminated water is described as having an increased biological oxygen demand (BOD) and water treatment is aimed at decreasing the BOD so as to make more oxygen available for fish and other life forms.

[0004]The most common method of increasing the oxygen content of a medium is by sparging with air or oxygen. While this is a simple method, the resulting large bubbles produced simply break the surface and are discharged into the atmosphere. Attempts have been made to reduce the size of the bubbles in order to facilitate oxygen transfer by increasing the total surface area of the oxygen bubbles. U.S. Pat. No. 5,534,143 discloses a microbubble generator that achieves a bubble size of about 0.10 millimeters to about 3 millimeters in diameter. U.S. Pat. No. 6,394,429 ("the '429 patent") discloses a device for producing microbubbles, ranging in size from 0.1 to 100 microns in diameter, by forcing air into the fluid at high pressure through a small orifice.

[0005]When the object of generating bubbles is to oxygenate the water, either air, with an oxygen content of about 21%, or pure oxygen may be used. The production of oxygen and hydrogen by the electrolysis of water is well known. A current is applied across an anode and a cathode which are immersed in an aqueous medium. The current may be a direct current from a battery or an AC/DC converter from a line. Hydrogen gas is produced at the cathode and oxygen gas is produced at the anode. The reactions are:

[SIZE=+1]AT THE CATHODE[/SIZE]: 4H2O+4e-→4OH-+2H2

[SIZE=+1]AT THE ANODE[/SIZE]: 2H2O→O2+4H++4e.sup.

[SIZE=+1]NET REACTION[/SIZE]: 6H2O→4OH-+4H+++2H2+O2

286 kilojoules of energy is required to generate one mole of oxygen.

[0006]The gasses form bubbles which rise to the surface of the fluid and may be collected. Either the oxygen or the hydrogen may be collected for various uses. The "electrolytic water" surrounding the anode becomes acidic while the electrolytic water surrounding the cathode becomes basic. Therefore, the electrodes tend to foul or pit and have a limited life in these corrosive environments.

[0007]Many cathodes and anodes are commercially available. U.S. Pat. No. 5,982,609 discloses cathodes comprising a metal or metallic oxide of at least one metal selected from the group consisting of ruthenium, iridium, nickel, iron, rhodium, rhenium, cobalt, tungsten, manganese, tantalum, molybdenum, lead, titanium, platinum, palladium and osmium. Anodes are formed from the same metallic oxides or metals as cathodes. Electrodes may also be formed from alloys of the above metals or metals and oxides co-deposited on a substrate. The cathode and anodes may be formed on any convenient support in any desired shape or size. It is possible to use the same materials or different materials for both electrodes. The choice is determined according to the uses. Platinum and iron alloys ("stainless steel") are often preferred materials due to their inherent resistance to the corrosive electrolytic water. An especially preferred anode disclosed in U.S. Pat. No. 4,252,856 comprises vacuum deposited iridium oxide.

[0008]Holding vessels for live animals generally have a high population of animals which use up the available oxygen rapidly. Pumps to supply oxygen have high power requirements and the noise and bubbling may further stress the animals. The available electrolytic generators likewise have high power requirements and additionally run at high voltages and produce acidic and basic water which are detrimental to live animals. Many of the uses of oxygenators, such as keeping bait or caught fish alive, would benefit from portable devices that did not require a source of high power. The need remains for quiet, portable, low voltage means to oxygenate water.

[0009]It has also been known that plant roots are healthier when oxygenated water is applied. It is thought that oxygen inhibits the growth of deleterious fungi. The water sparged with air as in the '429 patent was shown to increase the biomass of hydroponically grown cucumbers and tomatoes by about 15%.

[0010]The need remains for oxygenator models suitable to be placed in-line in water distribution devices so as to be applied to field as well as hydroponic culture.

[SIZE=+1]SUMMARY OF THE INVENTION[/SIZE]

[0011]This invention provides an oxygen emitter which is an electrolytic cell which generates very small microbubbles and nanobubbles of oxygen in an aqueous medium, which bubbles are too small to break the surface tension of the medium, resulting in a medium supersaturated with oxygen.

[0012]The electrodes may be a metal or oxide of at least one metal selected from the group consisting of ruthenium, iridium, nickel, iron, rhodium, rhenium, cobalt, tungsten, manganese, tantalum, molybdenum, lead, titanium, platinum, palladium and osmium or oxides thereof. The electrodes may be formed into open grids or may be closed surfaces. The most preferred cathode is a stainless steel mesh. The most preferred mesh is a 1/16 inch grid. The most preferred anode is platinum and iridium oxide on a support. A preferred support is titanium.

[0013]In order to form microbubbles and nanobubbles, the anode and cathode are separated by a critical distance. The critical distance ranges from 0.005 inches to 0.140 inches. The preferred critical distance is from 0.045 to 0.060 inches.

[0014]Models of different size are provided to be applicable to various volumes of aqueous medium to be oxygenated. The public is directed to choose the applicable model based on volume and power requirements of projected use. Those models with low voltage requirements are especially suited to oxygenating water in which animals are to be held.

[SIZE=+1]Controls are provided to regulate the current and timing of electrolysis[/SIZE].

[0015]A flow-through model is provided which may be connected in-line to a watering hose or to a hydroponic circulating system. The flow-through model can be formed into a tube with triangular cross-section. In this model, the anode is placed toward the outside of the tube and the cathode is placed on the inside, contacting the water flow. Alternatively, the anodes and cathodes may be in plates parallel to the long axis of the tube, or may be plates in a wafer stack. Alternately, the electrodes may be placed in a side tube ("T" model) out of the direct flow of water. Protocols are provided to produce superoxygenated water at the desired flow rate and at the desired power usage. Controls are inserted to activate electrolysis when water is flowing and deactivate electrolysis at rest.

[0016]This invention includes a method to promote growth and increase yield of plants by application of superoxygenated water. The water treated with the emitter of this invention is one example of superoxygenated water. Plants may be grown in hydroponic culture or in soil. The use of the flow-through model for drip irrigation of crops and waste water treatment is disclosed.

[SIZE=+1]BRIEF DESCRIPTION OF THE DRAWINGS[/SIZE]

[0017]FIG. 1 is the O2 emitter of the invention.

[0018]FIG. 2 is an assembled device.

[0019]FIG. 3 is a diagram of the electronic controls of the O2 emitter.

[0020]FIG. 4 shows a funnel or pyramid variation of the O2 emitter.

[0021]FIG. 5 shows a multilayer sandwich O2 emitter.

[0022]FIG. 6 shows the yield of tomato plants watered with superoxygenated water.

[0023]FIG. 7 shows an oxygenation chamber suitable for flow-through applications. FIG. 7A is a cross section showing arrangement of three plate electrodes. FIG. 7B is a longitudinal section showing the points of connection to the power source.

[0024]FIG. 8 is a graph showing the oxygenation of waste water.

[SIZE=+1]DETAILED DESCRIPTION OF THE INVENTION[/SIZE]

[SIZE=+1]Definitions[/SIZE]

[0025]For the purpose of describing the present invention, the following terms have these meanings:

[0026]Critical distance" means the distance separating the anode and cathode at which evolved oxygen forms microbubbles and nanobubbles.

[0027]Critical distance" means the distance separating the anode and cathode at which evolved oxygen forms microbubbles and nanobubbles.

[0028]O2 emitter" means a cell comprised of at least one anode and at least one cathode separated by the critical distance.

[0029]Metal" means a metal or an alloy of one or more metals.

[0030]Microbubble" means a bubble with a diameter less than 50 microns.

[0031]Nanobubble" means a bubble with a diameter less than that necessary to break the surface tension of water. Nanobubbles remain suspended in the water, giving the water an opalescent or milky appearance.

[0032]Supersaturated" means oxygen at a higher concentration than normal calculated oxygen solubility at a particular temperature and pressure.

[0033]Superoxygenated water" means water with an oxygen content at least 120% of that calculated to be saturated at a temperature.

[0034]Water" means any aqueous medium with resistance less than one ohm per square centimeter; that is, a medium that can support the electrolysis of water. In general, the lower limit of resistance for a medium that can support electrolysis is water containing more than 2000 ppm total dissolved solids.

[0035]The present invention produces microbubbles and nanobubbles of oxygen via the electrolysis of water. As molecular oxygen radical (atomic weight 8) is produced, it reacts to form molecular oxygen, O2. In the special dimensions of the invention, as explained in more detail in the following examples, O2 forms bubbles which are too small to break the surface tension of the fluid. These bubbles remain suspended indefinitely in the fluid and, when allowed to build up, make the fluid opalescent or milky. Only after several hours do the bubbles begin to coalesce on the sides of the container and the water clears. During that time, the water is supersaturated with oxygen. In contrast, the H2 formed readily coalesces into larger bubbles which are discharged into the atmosphere, as can be seen by bubble formation at the cathode.

[0036]The first objective of this invention was to make an oxygen emitter with low power demands, low voltage and low current for use with live animals. For that reason, a small button emitter was devised. The anode and cathode were set at varying distances. It was found that electrolysis took place at very short distances before arcing of the current occurred. Surprisingly, at slightly larger distances, the water became milky and no bubbles formed at the anode, while hydrogen continued to be bubbled off the cathode. At distance of 0.140 inches between the anode and cathode, it was observed that the oxygen formed bubbles at the anode. Therefore, the critical distance for microbubble and nanobubble formation was determined to be between 0.005 inches and 0.140 inches.

[SIZE=+1]EXAMPLE [/SIZE]1

[SIZE=+1]Oxygen Emitter[/SIZE]

[0037]As shown in FIG. 1, the oxygen evolving anode 1 selected as the most efficient is an iridium oxide coated single sided sheet of platinum on a support of titanium (Eltech, Fairport Harbor, Ohio). The cathode 2 is a (fraction ( 1/16)} inch mesh (size 8 mesh) marine stainless steel screen. The anode and cathode are separated by a non-conducting spacer 3 containing a gap 4 for the passage of gas and mixing of anodic and cathodic water and connected to a power source through a connection point 5. FIG. 2 shows a plan view of the assembled device. The O2 emitter 6 with the anode connecting wire 7 and the cathode connecting wire 8 is contained in an enclosure 9, connected to the battery compartment 10. The spacer thickness is critical as it sets the critical distance. It must be of sufficient thickness to prevent arcing of the current, but thin enough to separate the electrodes by no more than 0.140 inches. Above that thickness, the power needs are higher and the oxygen bubbles formed at higher voltage will coalesce and escape the fluid. Preferably, the spacer is from 0.005 to 0.075 inches thick. At the lower limits, the emitter tends to foul more quickly. Most preferably, the spacer is about 0.050 inches thick. The spacer may be any nonconductive material such as nylon, fiberglass, Teflon®. polymer or other plastic. Because of the criticality of the space distance, it is preferable to have a non-compressible spacer. It was found that Buna, with a durometer measure of 60 was not acceptable due to decomposition. Viton, a common fluoroelastomer, has a durometer measure of 90 and was found to hold its shape well.

[0038]In operation, a small device with an O2 emitter 1.485 inches in diameter was driven by 4AA batteries. The critical distance was held at 0.050 inches with a Viton spacer. Five gallons of water became saturated in seven minutes. This size is suitable for raising oxygen levels in an aquarium or bait bucket.

[0039]It is convenient to attach a control circuit which comprises a timer that is thermostatically controlled by a temperature sensor which determines the off time for the cathode. When the temperature of the solution changes, the resistance of the thermistor changes, which causes an off time of a certain duration. In cool water, the duration is longer so in a given volume, the emitter generates less oxygen. When the water is warmer and therefore hold less oxygen, the duration of off time is shorter. Thus the device is self-controlled to use power most economically. FIG. 3 shows a block diagram of a timer control with anode 1, cathode 2, thermistor temperature sensor 3, timer control circuit 4 and wire from a direct current power source 5.

[SIZE=+1]EXAMPLE [/SIZE]2

[SIZE=+1]Measurement of O[/SIZE]2 Bubbles

[0040]Attempts were made to measure the diameter of the O2 bubbles emitted by the device of Example 1. In the case of particles other than gasses, measurements can easily be made by scanning electron microscopy, but gasses do not survive electron microscopy. Large bubble may be measured by pore exclusion, for example, which is also not feasible when measuring a gas bubble. A black and white digital, high contrast, backlit photograph of treated water with a millimeter scale reference was shot of water produced by the emitter of Example 1. About 125 bubbles were seen in the area selected for measurement. Seven bubbles ranging from the smallest clearly seen to the largest were measured. The area was enlarged, giving a scale multiplier of 0.029412.

[0041]Recorded bubble diameters at scale were 0.16, 0.22, 0.35, 0.51, 0.76, 0.88 and 1.09 millimeters. The last three were considered outliers by reverse analysis of variance and were assumed to be hydrogen bubbles. When multiplied by the scale multiplier, the assumed O2 bubbles were found to range from 4.7 to 15 microns in diameter. This test was limited by the resolution of the camera and smaller bubbles in the nanometer range could not be resolved. It is known that white light cannot resolve features in the nanometer size range, so monochromatic laser light may give resolution sensitive enough to measure smaller bubbles. Efforts continue to increase the sensitivity of measurement so that sub-micron diameter bubbles can be measured.

[SIZE=+1]EXAMPLE [/SIZE]3

[SIZE=+1]Other Models of Oxygen Emitter[/SIZE]

[0042]Depending on the volume of fluid to be oxygenated, the oxygen emitter of this invention may be shaped as a circle, rectangle, cone or other model. One or more may be set in a substrate that may be metal, glass, plastic or other material. The substrate is not critical as long as the current is isolated to the electrodes by the nonconductor spacer material of a thickness from 0.005 to 0.075 inches, preferably 0.050 inches. It has been noticed that the flow of water seems to be at the periphery of the emitter, while the evolved visible bubbles (H2) arise at the center of the emitter. Therefore, a funnel or pyramidal shaped emitter was constructed to treat larger volumes of fluid. FIG. 4 is a cross sectional diagram of such an emitter. The anode 1 is formed as an open grid separated from a marine grade stainless steel screen cathode 2 by the critical distance by spacer 3 around the periphery of the emitter and at the apex. This flow-through embodiment is suitable for treating large volumes of water rapidly.

[0043]The size may be varied as required. A round emitter for oxygenating a bait bucket may be about 2 inches in diameter, while a 3-inch diameter emitter is adequate for oxygenating a 10 to 40 gallon tank. The live well of a fishing boat will generally hold 40 to 80 gallons of water and require a 4-inch diameter emitter. It is within the scope of this invention to construct larger emitters or to use several in a series to oxygenate larger volumes. It is also within the scope of this invention to vary the model to provide for low voltage and amperage in cases where the need for oxygen is moderate and long lasting or conversely, to supersaturate water very quickly at higher voltage and amperage. In the special dimensions of the present invention, it has been found that a 6 volt battery supplying a current as low as 40 milliamperes is sufficient to generate oxygen. Such a model is especially useful with live plants or animals, while it is more convenient for industrial use to use a higher voltage and current. Table I shows a number of models suitable to various uses.

[SIZE=+1]TABLE[/SIZE]-US-00001 TABLE I Emitter Model Gallons Volts Amps Max. Ave Watts Bait keeper 5 6 0.090 0.060 0.36 Livewell 32 12 0.180 0.120 1.44 OEM 2 inch 10 12 0.210 0.120 1.44 Bait store 70 12 0.180 0.180 2.16 Double cycle 2 12 0.180 0.180 2.16 OEM 3 inch 50 12 0.500 0.265 3.48 OEM 4 inch 80 12 0.980 0.410 4.92 Water pail 2 24 1.200 1.200 28.80 Plate 250 12 5.000 2.500 30.00

[SIZE=+1]EXAMPLE [/SIZE]4

[SIZE=+1]Multilayer Sandwich O[/SIZE]2 Emitter

[0044]An O2 emitter was made in a multilayer sandwich embodiment. (FIG. 5) An iridium oxide coated platinum anode 1 was formed into a grid to allow good water flow and sandwiched between two stainless steel screen cathodes 2. Spacing was held at the critical distance by nylon spacers 3. The embodiment illustrated is held in a cassette 4 which is secured by nylon bolt 5 with a nylon washer 6. The dimensions selected were:

[SIZE=+1]TABLE[/SIZE]-US-00002 cathode screen 0.045 inches thick nylon spacer 0.053 inches thick anode grid 0.035 inches thick nylon spacer 0.053 inches thick cathode screen 0.045 inches thick,

[SIZE=+1]for an overall emitter thickness of [/SIZE]0.231 inches thick inches.

[0045]If a more powerful emitter is desired, it is within the scope of this invention to repeat the sequence of stacking. For example, an embodiment may easily be constructed with this sequence: cathode, spacer, anode, spacer, cathode, spacer, anode, spacer, cathode, spacer, anode, spacer, cathode. The number of layers in the sandwich is limited only by the power requirements acceptable for an application.

[SIZE=+1]EXAMPLE [/SIZE]5

[SIZE=+1]Effect of Superoxygenated Water on the Growth of Plants[/SIZE]

[0046]It is known that oxygen is important for the growth of plants. Although plants evolve oxygen during photosynthesis, they also have a requirement for oxygen for respiration. Oxygen is evolved in the leaves of the plants, while often the roots are in a hypoxic environment without enough oxygen to support optimum respiration, which can be reflected in less than optimum growth and nutrient utilization. Hydroponically grown plants are particularly susceptible to oxygen deficit in the root system. U.S. Pat. No. 5,887,383 describes a liquid supply pump unit for hydroponic cultures which attain oxygen enrichment by sparging with air. Such a method has high energy requirements and is noisy. Furthermore, while suitable for self-contained hydroponic culture, the apparatus is not usable for field irrigation. In a report available on the web, it was shown that hydroponically grown cucumbers and tomatoes supplied with water oxygenated with a device similar to that described in the '429 patent had increased biomass of about 12% and 17% respectively. It should be noted that when sparged with air, the water may become saturated with oxygen, but it is unlikely that the water is superoxygenated.

[SIZE=+1]A[/SIZE]. Superoxygenated Water in Hydroponic Culture.

[0047]Two small hydroponic systems were set up to grow two tomato plants. Circulation protocols were identical except that the 21/2 gallon water reservoir for the Control plant was eroated with and aquarium bubbler and that for the Test plant was oxygenated with a five-inch strip emitter for two minutes prior to pumping. The cycle was set at four minutes of pumping, followed by four minutes of rest. The control water had an oxygen content of about 97% to 103% saturation, that is, it was saturated with oxygen. The test water had an oxygen content of about 153% to 165% saturation, that is, it was supersaturated. The test plant was at least four times the volume of the control plant and began to show what looked like fertilizer burn. At that point the fertilizer for the Test plant was reduced by half. Since the plants were not exposed to natural light but to continuous artificial light in an indoor environment without the natural means of fertilization (wind and/or insects), the experiment was discontinued after three months. At that time, the Test plant but not the Control plant had blossomed.

[SIZE=+1]B[/SIZE]. Superoxygenated Water in Field Culture.

[0048]A pilot study was designed to ascertain that plants outside the hydroponic culture facility would benefit from the application of oxygen. It was decided to use water treated with the emitter of Example 1 as the oxygen carrier. Since water so treated is supersaturated, it is an excellent carrier of oxygen.

[0049]Tomato seeds (Burpee "Big Boy") were planted in one-inch diameter peat and dirt plugs encased in cheese cloth and placed in a tray in a southwest window. Controls were watered once a day with tap water ("Control") or oxygenated water ("Test"). Both Controls and Test sprouted at one week. After five weeks, the Test plants were an average of 11 inches tall while the Controls were an average of nine inches tall. At this time, May 10, when the threat of frost in Minnesota was minimal, the plants were transplanted to 13 inch diameter pots with drainage holes. Four inches of top soil was added to each pot, topped off with four inches of Scott's Potting Soil. The pots were placed outside in a sunny area with at least eight hours a day of full sun. The plants were watered as needed with either plain tap water (Control) or oxygenated water (Test). The oxygenated water was produced by use of the emitter of Example 1 run for one-half hour in a five-gallon container of water. Previous experiments showed that water thus treated had an oxygen content from 160% to 260% saturation. The Test plants flowered on June 4, while the Controls did not flower until June 18. For both groups, every plant in the group first had flowers on the same day. All plants were fertilized on July 2 and a soaker hose provided because the plants were now so big that watering by hand was difficult. The soaker hose was run for one half to one hour each morning, depending on the weather, to a point at which the soil was saturated with water. One half hour after the soaker hose was turned off, about 750 ml of superoxygenated water was applied to each of the Test plants.

[0050]The Test plants were bushier than the Controls although the heights were similar. At this time, there were eight Control plants and seven Test plants because one of the Test plants broke in a storm. On July 2, the control plants averaged about 17 primary branches from the vine stem, while the control plants averaged about 13 primary branches from the vine stem. As the tomatoes matured, each was weighed on a kitchen scale at harvest. The yield history is shown in Table II.

[SIZE=+1]TABLE[/SIZE]-US-00003 TABLE II Test, grams Control, grams tomatoes from seven tomatoes from eight plants/cumulative Week of: plants/cumulative total total July 27 240 400 August 3 180 420 2910 3310 August 10 905 1325 1830 5140 August 17 410 1735 2590 7730 August 24 3300 5035 2470 10200 August 31 4150 9175 1580 11780 September 15 not weighed 3710 15490 Final Harvest September 24 6435 15620 8895 24385

[0051]The total yield for the eight Control plants was 15620 grams or 1952 grams of tomatoes per plant.

[0052]The total yield for the seven Test plants was 24385 grams or 3484 grams of tomatoes per plant, an increase in yield of about 79% over the Control plants.

[0053]FIG. 6 shows the cumulative total as plotted against time. Not only did the Test plants blossom and bear fruit earlier, but that the Control plants never caught up to the test plants in the short Minnesota growing season. It should be noted that the experiment was terminated because of predicted frost. All fruits, both green and red, were harvested and weighed at that point.

[SIZE=+1]EXAMPLE [/SIZE]6

[SIZE=+1]Flow[/SIZE]-Through Emitter for Agricultural Use

[0054]In order to apply the findings of example 5 to agricultural uses, an emitter than can oxygenate running water efficiently was developed. In FIG. 7(A), the oxygenation chamber is comprised of three anodes 1 and cathodes 2, of appropriate size to fit inside a tube or hose and separated by the critical distance are placed within a tube or hose 3 at 120° angles to each other. The anodes and cathodes are positioned with stabilizing hardware 4. The stabilizing hardware, which can be any configuration such as a screw, rod or washer, is preferably formed from stainless steel. FIG. 7(B) shows a plan view of the oxygenation chamber with stabilizing hardware 4 serving as a connector to the power source and stabilizing hardware 5 serving as a connector to the power source. The active area is shown at 6.

[0055]This invention is not limited to the design selected for this embodiment. Those skilled in the art can readily fabricate any of the emitters shown in FIG. 4 or 5, or can design other embodiments that will oxygenate flowing water. One useful embodiment is the "T" model, wherein the emitter unit is set in a side arm. The emitted bubbles are swept into the water flow. The unit is detachable for easy servicing. Table III shows several models of flow through emitters. The voltage and flowrates were held constant and the current varied. The Dissolved oxygen (DO) from the source was 7.1 mg/liter. The starting temperature was 12.2° C. but the flowing water cooled slightly to 11 or 11.5° C. Without undue experimentation, anyone may easily select the embodiment that best suits desired characteristics from Table III or designed with the teachings of Table III.

[SIZE=+1]TABLE[/SIZE]-US-00004 TABLE III ACTIVE DO OF* ELECTRODE CURRENT, FLOW RATE SAMPLE AT MODEL AREA, SQ.IN. VOLTAGE AMPS. GAL/MINUTE ONE MINUTE 2-Inch "T" 2 28.3 0.72 12 N/A 3-inch "T" 3 28.3 1.75 12 N/A 2-plate Tube 20 28.3 9.1 12 8.4 3-Plate tube 30 28.3 12.8 12 9.6 *As the apparatus runs longer, the flowing water becomes milky, indicating supersaturation. The one-minute time point shows the rapid increase in oxygenation.

[0056]The following plants will be tested for response to superoxygenated water: grape vines, lettuce, and radishes in three different climate zones. The operators for these facilities will be supplied with units for drip irrigation. Drip irrigation is a technique wherein water is pumped through a pipe or hose with perforations at the site of each plant to be irrigated. The conduit may be underground or above ground. Since the water is applied directly to the plant rather than wetting the entire field, this technique is especially useful in arid climates or for plants requiring high fertilizer applications.

[0057]The superoxygenated water will be applied by drip irrigation per the usual protocol for the respective plants. Growth and yield will be compared to the same plants given only the usual irrigation water. Pest control and fertilization will be the same between test and control plants, except that the operators of the experiments will be cautioned to be aware of the possibility of fertilizer burn in the test plants and to adjust their protocols accordingly.

[0058]It is expected that the superoxygenated plants with drip irrigation will show more improved performance with more continuous application of oxygen than did the tomato plants of Example 5, which were given superoxygenated water only once a day.

[SIZE=+1]EXAMPLE [/SIZE]7

[SIZE=+1]Treatment of Waste Water[/SIZE]

[0059]Waste water, with a high organic content, has a high BOD, due to the bacterial flora. It is desirable to raise the oxygen content of the waste water in order to cause the flora to flocculate. However, it is very difficult to effectively oxygenate such water. Using a 4 inch OEM (see Table I) with a 12 volt battery, four liters of waste water in a five gallon pail were oxygenated. As shown in FIG. 8, the dissolved oxygen went from 0.5 mg/l to 10.8 mg/l in nine minutes.

[0060]Those skilled in the art will readily comprehend that variations, modifications and additions may in the embodiments described herein may be made. Therefore, such variations, modifications and additions are within the scope of the appended claims.




Patents by PATTERSON, THUENTE, SKAAR & CHRISTENSEN, P.A.
0.0
8.0
16.0
24.0
32.0
40.0
2001-04
2002-06
2003-07
2004-08
2005-09
2006-10
2007-11
2008-12








Patents by James Andrew Senkiw
0.0
0.2
0.4
0.6
0.8
1.0
2003-09
2004-06
2006-07
2008-07
2008-08








Patents in all subclasses WITH TIME CONTROL



Read more: http://www.faqs.org/patents/app/20080202995#ixzz0kB7AfgZX
 

SHOSHON3N8TV

Active Member
Oh hell yeah Tea Tree! I think you are the only one who understands what I want to do! I also have the "special" anodes that do not rust/pit during the electrolysis process so i don't hafto worry about rusty water (in the generator) or the anode corroding-the cathode is some sort of stainless steel. So.... the "micro" bubbles are much betta than "regular-sized" bubbles made by air-stones...hmmm, I love how they tested it on tomatoes :bigjoint: Thanks for posting the info, gonna read it again..
 
Top