Considering that I measure room temps by levels and over years of runs. I like to hold about a 72F ambient. I get higher 70's at the canopy and pot level, around 68-70F.
Room pressure is effected by Pos or Neg air pressure from how you use/move the air.
Just started to use a minisplit in one of the rooms I run. This has made me run an exhaust for 5 min on the top of the hr, during lights on. This is to draw in fresh O2, as depletion is now a factor. I quickly found that in the ripening stage. It's better to slow that turn over down some (helps keep the ethylene gas [ripening agent] able to do it's job). I now get an on time/stable and predictable finish. It also made me do more in the way of keeping "like" running strains in that room for better consistency in the perpetual harvest rotations I run.
As for keeping the RH up to help check PM?
It didn't work as well as it was supposed to. I get the feeling the piece was written by book learn'en and not so much from real experience. Odd too, cause the guy that wrote it - IS a commercial grower....
Tbf I was also starting to wonder where you had got too. Like good old uncle Buck I figured you'd had enough of RIU
I have some questions for you or anybody that can answer. Maybe it will help others too.
As far as I am aware cob/led need to run higher temps and also higher humidity.
In the past I ran inkbird thermal cut off>volt stepped lowest flow out-take at 75f (77peak) and 50%RH (55 peak). This lower range of temps just made sense for climate energy costs +fear of high rh. I have always had small outbreaks of mold if RH gets too high with bigger buds. On the flip side if things get a little too dry this seems to give small outbreaks of botrytis. I ''think'' this is related to a few leaves suffering to over respiration/wind drying out the leaf stem in the bud and then being an easy target for bot. I deliberatly run lower RH and reduced PPM to account for higher respiration, it was an effort to keep mold down (perhaps a misplaced one). I normally expect 1-2% total loss to mold or bot but also have runs with no issues, seems to depend on time of year or particular bud size. However this was always acceptable loss to me since why change anything and risk a catastrophic 50%+ loss kinda deal. I didn't add any additional canopy air flow because of my above resp/wind dry bot ''theory'' for example, but no doubt it will be needed to run higher RH. The reason I mentioned that idea about bot is becuase when I read you taling about the pretective wax layer it made a lot of sense in that way. Doesn't mean I am right ofc.. but it's one more reason for me to stop being a pussy and try to run higher rh.
Recently I began paying a lot more attention to vpd and decided to give it a real shot, since I know the above isn't optimal. My biggest fear keeping me from following vpd has and always will be mold, pm so far has never been an issue (although it may be now with potential high rh swings). Everything I read up til that point was mold hazards of RH being too high. Now I am reading things like maintaining a steady RH will not give mold (with good airflow ofc) and ward off pm, should that become an issue.
The cycle I have now is temp set to 78-80 peak. Rh set to 65-70 peak (although extraction brings it down to low 60's, not sure if that's ok). Extraction is off for around 10 min as lights raise ambiant, then kicks in for about 2 to 3 min bringing temp to 78, the umidity climbs quite quickly once outake shuts off. In the winter this will be more like extraction off for 30 min, extraction on for 1 min. I am ok with these extraction off cycles letting the lights raise temps rather than blasting another 2k of heating, all I care about is no mold. I'm just explaining the set-up so people can comment on the RH swings or levels.
From what I've read recently here on RIU (correct my conclusions) lights off temp should sit at around 70f minimum. I will also change light timers so the light units individually switch off in 10 min intervals in order to stop a massive heat drop>due point. This should give heater time to level ambient out before total darkness. Keeping RH at 65% over night is what I need to be doing? how much of a swing is too much?.
I also don't use a mold filter for my in-take, this is probably something mandatory to get sorted too?.
On the pluss side I can absolutely confirm what others have said about keeping in the upper vpd range. For the first few weeks flower I let it run 80f 75rh and have never seen anything like it for pre flower growth, caught me completely off gaurd.