(Poll) Lightning 4'x8'. 1000w HPS or 315CMH+600w HPS?

Running 2 plant Scrog with a 4'x8' space available how would you choose to light it and why?

  • A 1000W SE HPS

    Votes: 1 25.0%
  • A 600w SE HPS + 315w CMH

    Votes: 3 75.0%

  • Total voters
    4

.Smoke

Well-Known Member
I already have the lights. I could use a little help/advice here to make a final decision.
Just wanting to see if there are any pros/cons either way I haven't considered yet.

Thanks for your time.
 

KingQuazy

Well-Known Member
The only right answer here is a question. Is this for full cycle, or flowering only?

Flowering only, people can and will argue each way. Rightfully so. I went 1000w hps but I know I'm eventually going to supplement UV with cmh or aquarium tubes. But one can argue that the 85w is more than made up for with the cmh's extra spectrum and efficiency of the 600w.

But if we're talking for full cycle grow.. it's gotta be the 600&315. I do not miss the days of full cycle hps grows:?
 

.Smoke

Well-Known Member
The only right answer here is a question. Is this for full cycle, or flowering only?

Flowering only, people can and will argue each way. Rightfully so. I went 1000w hps but I know I'm eventually going to supplement UV with cmh or aquarium tubes. But one can argue that the 85w is more than made up for with the cmh's extra spectrum and efficiency of the 600w.

But if we're talking for full cycle grow.. it's gotta be the 600&315. I do not miss the days of full cycle hps grows:?
It's for my flower tent.
I'm actually serious. If you can deal with the heat and electricity. I'd put the 1000 in the middle, and the other 2 kinda angled at the ends.
If I was going that route, I'd just run 2 of my 1kW HPS. :)
I'm just having trouble trying to decide how best to manage a 4'x8' flower tent running 2 plants, all medium/tall size strains, with a 10ish week veg time, Scrog with the best coverage but least amount of "unneeded" light.
I have a 315cmh, 2-600hps and 2-1kW hps availible to use, I just can't decide how to best utilize them...1-1kW? 2-600w? 600/315?
I don't expect to fill "all" of the tent per se, but... who knows.

Any suggestions are welcomed.
 

PadawanWarrior

Well-Known Member
It's for my flower tent.

If I was going that route, I'd just run 2 of my 1kW HPS. :)
I'm just having trouble trying to decide how best to manage a 4'x8' flower tent running 2 plants, all medium/tall size strains, with a 10ish week veg time, Scrog with the best coverage but least amount of "unneeded" light.
I have a 315cmh, 2-600hps and 2-1kW hps availible to use, I just can't decide how to best utilize them...1-1kW? 2-600w? 600/315?
I don't expect to fill "all" of the tent per se, but... who knows.

Any suggestions are welcomed.
Oh I didn't know you had 2 1000's already.
 

PadawanWarrior

Well-Known Member
Just insinuating that the poll options aren't really appropriate for the space. Probably toss them all in there but the coverage areas of the 315 and 600 aren't really ideal for a 4 foot width.
I thought the same thing about the poll, so I didn't answer it. I just found out he has 2 1000's already. I would have picked that option if that was a choice in the poll.
 

Renfro

Well-Known Member
I have a 315cmh, 2-600hps and 2-1kW hps availible to use, I just can't decide how to best utilize them...1-1kW? 2-600w? 600/315?
Each 1kW SE is great over a 4x4, two and you nailed a 4x8. Use the other lights for veg perhaps, they are each good for a 3x3 (315 a cunt hair less and 600 a cunt hair more).
 

Renfro

Well-Known Member
I thought the same thing about the poll, so I didn't answer it. I just found out he has 2 1000's already. I would have picked that option if that was a choice in the poll.
Yeah I didn't answer the poll either. With the 600 or 315 he's sacrificing the 6 inches on each edge, just not good for the 4 foot width, unless just vegging.
 

.Smoke

Well-Known Member
I thought the same thing about the poll, so I didn't answer it. I just found out he has 2 1000's already. I would have picked that option if that was a choice in the poll.
Just insinuating that the poll options aren't really appropriate for the space. Probably toss them all in there but the coverage areas of the 315 and 600 aren't really ideal for a 4 foot width.
I do agree it's a bit biased. I do have 2- 1kW I have in there atm, but even with Gorilla Glue, Blue Dream, Granddaddy Purple and White Widow, I don't see 1 plant producing 1000 grams so 2x 1kW seems like overkill to me no?
 

J232

Well-Known Member
I do agree it's a bit biased. I do have 2- 1kW I have in there atm, but even with Gorilla Glue, Blue Dream, Granddaddy Purple and White Widow, I don't see 1 plant producing 1000 grams so 2x 1kW seems like overkill to me no?
I don’t know, I have a 600 and a 1k de in 6x6 and would like to do a 1k and put 2 315s in there or 2 1k’s
 

Renfro

Well-Known Member
Remember, you are lighting an area, and using less than 50 watts per sqft of HPS is leaving yield on the table. A 600 would be 37.5 watts per sqft, no bueno for flower.
 

Renfro

Well-Known Member
I don’t know, I have a 600 and a 1k de in 6x6 and would like to do a 1k and put 2 315s in there or 2 1k’s
Any of those is under lit for 36 sqft. Thing about a 6x6 is you really would do best with 4 x 600 or 4 x 315 or a mix. The square footprint of the lights means each gets a 3x3.
 
Top