Another question I had was when you used the generators to power up the op did you have it indoors or outdoors & if so how did you control the carbon monoxide & the noise that they generate? Some generators have a 12 hour run time at the rated output & there DB rating is slightly a little bit louder than some fans, like 58-69 DB. I have done research on them & some people have said the more wattage you pull the noisier the DB will get. Any input you have would be appreciated. :peace:
 

abudsmoker

Well-Known Member
Another question I had was when you used the generators to power up the op did you have it indoors or outdoors & if so how did you control the carbon monoxide & the noise that they generate? Some generators have a 12 hour run time at the rated output & there DB rating is slightly a little bit louder than some fans, like 58-69 DB. I have done research on them & some people have said the more wattage you pull the noisier the DB will get. Any input you have would be appreciated. :peace:

This generator is underground. It has the back of a container, that whole container is worthless because of the odor. The Dig is offline ATM. Fuel is too expensive, and the property is being used for other things
 

southfloridasean

Well-Known Member
This generator is underground. It has the back of a container, that whole container is worthless because of the odor. The Dig is offline ATM. Fuel is too expensive, and the property is being used for other things
So do you think a basement or a closed bathroom with an exhaust fan would work good? If the bathroom were soundproofed would you think that would work?
 

abudsmoker

Well-Known Member
So do you think a basement or a closed bathroom with an exhaust fan would work good? If the bathroom were soundproofed would you think that would work?

My biggest problem is the CAT motor in the generator, uses more cfm then i could bring in. i had to use a intake stack for the generator and a exaust muffler
About 6 foot long, aside from that i have rigged a 1080 cfm fan to exaust that area, i used food service curtains found in walking coolers and such to create a buffer zone then i framed a wall to isolate the generator, the generator is supported in a vibration damper, running this unit underground elimated nearly all the noise. being these containers have a large buffer zone around and about 6 foot of top soil it merely sound like a outdoor AC at the most, underground in the container, you are overpowered my the smell, more over the noise is extremely loud.

In the Second container, moisture is the worse part.
Even with bio diesel @3.33 a gallon it is not gost effective to produce my own power.

A hard LESSON LEARNED
 

southfloridasean

Well-Known Member
My biggest problem is the CAT motor in the generator, uses more cfm then i could bring in. i had to use a intake stack for the generator and a exaust muffler
About 6 foot long, aside from that i have rigged a 1080 cfm fan to exaust that area, i used food service curtains found in walking coolers and such to create a buffer zone then i framed a wall to isolate the generator, the generator is supported in a vibration damper, running this unit underground elimated nearly all the noise. being these containers have a large buffer zone around and about 6 foot of top soil it merely sound like a outdoor AC at the most, underground in the container, you are overpowered my the smell, more over the noise is extremely loud.

In the Second container, moisture is the worse part.
Even with bio diesel @3.33 a gallon it is not gost effective to produce my own power.

A hard LESSON LEARNED
Thanks for the info Abud. I know I wont be doing 15kw, Im looking at about 7kw with a db rating of 69 so I probably wont need a 1080 cfm fan but more like a 772 cfm. I plan on using neoprene on the floor & walls along with sound proof material that they use for studios & run an extension cord to the op. Ill bring in the air to cool the generator from another area of the house. The unit below is what im looking at.
 

southfloridasean

Well-Known Member
1. 16.0 HP Air Cooled OHV Engine

16.0HP, 419cc, Air Cooled, OHV, 4 Stroke Engine With Low Oil Shutoff, Smooth Running, E-Start & EZ Pull Start Back Up.

2. Fully Enclosed Heavy Duty Rigid Steel Frame

Heavy Duty Rigid Steel Frame With Four Point Fully Isolated Motor Mounts For Smooth & Quiet Operation.

3. Long 24-Hour Run Time

Long 16-Hour Run Time At Full Rated Output.

Long 24-Hour Run Time At 50% Rated Output.

4. 10000W Surge Output

Surge AC Output: 10000W

Max. AC Output: 9250W

Rated AC Output: 8250W

With AVR to Consistent flow of 120/240V Power at Different Loads

5. 13.0 Gallon Tank With Gauge

All Steel 13.0 Gallon Fuel Tank with EZ-Read Gauge

6. Decibel: 66dBA

Super Quiet Muffler With Spark Arrestor Reduces Engine Noise.

7. Full Power Panel

Full Power Panel with Engine Shutoff Switch, Voltmeter, Hour meter, Voltage Selector, AC Circuit Breaker AC & DC Receptacle, AC & DC Circuit Protector & Power Outlets.

8. 4 Pole Single Phase 120V AC & 1 Pole 120V/240V AC & 1 Pole 12V DC Output Generator

Fully Protected 2 Pole 120V/ 60Hz Max Current 20A AC Output (NEMA 5-20R)

1 Pole 120V/ 60Hz Max Current 30A AC Output (NEMA L5-30R)

1 Pole 120V/ 60Hz Max Current 50A AC Output (NEMA 10-50R)

1 Pole 120/240V Max Current 30A AC Output (NEMA L14-30R)

1 Pole 12V DC with Max Current 8.3A DC Battery Recharging Cables Included.

9. Idle Control Saves Fuel

New Tech Throttle With Idle Control Saves Fuel & Reduces Noise

10. Portability Wheel / Foldable Handle Bar Kit Included

Two 10” Wheels & Handle Bar, Instructions Included

11. Easy Run A Variety Of Electric Appliances & Tools

Great for: Remote Areas, Construction Sites, Outdoor Activities, Emergency Power

12. One Year Warranty For Residential.

Three Months Warranty for Commercial

13. Package Size: 34″×27″×32″

Gross Weight: 250 lbs.
 

Attachments

abudsmoker

Well-Known Member
ok sorry not ignoring anyone, media is on the memory card, i have a few odd jobs to go complete when i get home a full update, The cloning of the new hydro system
Day one flowering on a new project, The new DWC supplies, 3 new food products,
oh yea update the thread......


Like i said really really busy. hold tight...... Eye candy as soon as im home showered and high......
 