LOL. Personally I cut the top off of my tent and just blow heat off the fixture before it hits the canopy, works fine. Also happy plants don't stink and carbon filters would be a waste of money IMO. Unless perhaps you are venting outside of the room.The filter would be sized for 440. Each branch would be the same and the common discharge would be the sum of both, so 880. This is going to be somewhat lower due to friction loss. Your single pipe should really be like 10" min and that would be noisey. 800 cfm is a lot of air lol.
You vent your lights back into your tent?LOL. Personally I cut the top off of my tent and just blow heat off the fixture before it hits the canopy, works fine. Also happy plants don't stink and carbon filters would be a waste of money IMO. Unless perhaps you are venting outside of the room.
Wye adaptors are made for optimal airflow to the outlet...The problem I see there is that you blowing the hot air back to the wye adapter. And then you will drag the hot air back down to your light
My carbon filter in my current setup works great.........get a bigger tent..... or a smaller lighting and vent system.... what are you cooling? I have gotten away with decently cheap bathroom vent fans for exhausting smaller lights...
I dunno, after buying a new 6" filter n still having stank... i just gave up n punched a hole thru the brick to vent outside. Next I will get 8' of 6" stove pipe and a cap, will look like I got a wood burner in the basement that never gets used.... stink is released @ or above roof level
And... happy plants DO stink... during the last week while flushing and in a perpetual.... thats pretty much always, lol.
I run two sun system 315w LECs in an open tent, no venting needed, just a fan..You vent your lights back into your tent?
Not if both fans are running, doesn't work like that lolThe problem I see there is that you blowing the hot air back to the wye adapter. And then you will drag the hot air back down to your light
He didn't show it in the pic, but theres 2 fans.... may need a backflow flapper tho just to act as a check valve....The problem I see there is that you blowing the hot air back to the wye adapter. And then you will drag the hot air back down to your light
Them gotta hang/mount vertical? Special ballast or 400w mag style?I run two sun system 315w LECs in an open tent, no venting needed, just a fan..
Ao those lecs really do run a lot cooler???I run two sun system 315w LECs in an open tent, no venting needed, just a fan..
A lot of what people are saying is NOT neccesarily true. To truly give you an accurate answer I'd need to know the dimensions of all of your ducting.Okay, I am not an artist!
Lets say I have two 440 CFM fans. One for the carbon filter and one to cool lights going into a Wye Adapter. How will my final CFM be effected for matching CFM with a filter? I forgot to draw a fan for the light.
View attachment 3627681
And i spelled "adaptor" wrong lol
I have it before. I'd agree tho I've never thought of that glad I didn't put it after lol.dumb question....do you have the fan before or after the light. I can see the fan motor getting really hot from the lights if it is after.
6x6x6 wye (something weird )?
or
8x6x6 wye<---880 (approx)?
Lolol you changed it yes.The filter would be sized for 440. Each branch would be the same and the common discharge would be the sum of both, so 880. This is going to be somewhat lower due to friction loss. Your single pipe should really be like 10" min and that would be noisey. 800 cfm is a lot of air lol.
8x6x6 would help at least. Let me look up this equation...dumb question....do you have the fan before or after the light. I can see the fan motor getting really hot from the lights if it is after.
6x6x6 wye (something weird )?
or
8x6x6 wye<---880 (approx)?