my 3 stages of flower

superstoner1

Well-Known Member
hell no. perfect. but even using a 50gal res, with that many plants they will suck it dry in no time. i would split it into two systems, it would make it easier on you to maintain the ph and ppm, less stress on the plants, and if something does happen to a pump it is half, not all.
 

oceangreen

Well-Known Member
just find some plugs or stainless screws to plug the holes of sprayers you pull out. you will have a serious lack of spray from loss of pressure with that many.


With a stronger pump external I can maintain the pressure, but yeah I going to rebuild with 12 sprayers same design

Agreed?

Thx ss
 

oceangreen

Well-Known Member
Bro stick to what we are doing... It's the most efficient don't over do and over think. Run you design past SS, I'm sure he agrees with me
 

superstoner1

Well-Known Member
i run the ecoplus 1056gph pump for my veg unit and also one for my wort chillers and ice box. i use the 633gph ecoplus in the flower units and the 396 in the cloner. the 1056 should do good for you, just make sure the supply line from pump to spray bars is big enough to supply the splits to each unit. i use 1" from pump to valves, 3/"4 from valves to spray bar and spray bar is 1/2". this gives all three of my veg units even pressure and spray patterns.
 

oceangreen

Well-Known Member
Would this be enough..for the triple vegger

Fow rate upto 0.92 lps (3.3 m3/h)

it translates to 871 gph (3.3m3/h)

The height I am dealing with is 160cm or 1.6 meters

Yea I am talking external pumps...

That ecoplus flow is rated at .3 meters..
 

oceangreen

Well-Known Member
I mean i think there is room to play with gph for the triple system. I don't think more flow would cause any issues.. For example if you run the ecoplus 1584, there would probably be no issues but more heat in the Rez... But for an external setup no problem..
 

oceangreen

Well-Known Member
One other thing I am trying to do is switch all the flower systems to external pumps with a hose adaptor For drainage..
 

oceangreen

Well-Known Member
So

SS,

Doing the manifold Rebuild

Are we agreed on 12 sprayers per manifold on this design?
DenBosch sprayers.jpg

Or should I just go with ONE pipe across??

Lets go about to start cutting
 

superstoner1

Well-Known Member
if you are starting over either is fine i guess. i always have done the single cross bar, less is best is how i role.
 

oceangreen

Well-Known Member
jeez, I just finished the new manifolds.. that was hell...

One turned out crooked as heck...oh well in it goes... 12 sprayers..

I swear if anyone says i have too many sprayers now... I am gonna drink some PVC cement
 
Top