jonnynobody
Well-Known Member
I have two 2000w HID's, two 600w HID's, and two quantum boards at 1110W totaling 4310w of power draw. I had a timer jump time a few days ago and while I was watering in the dark one of my 1000w lamps kicked on 2 hours ahead of schedule. I quickly disconnected it, threw away the timer, and replaced it with a new functional timer. However the experience scared the shit out of me, and made me quickly realize I need a light controller. The only issue I seem to be running into is that I have two LED quantum boards that are 120v. Every light controller I've looked at operates at 240v. My HID ballasts are all 120/240v compatible, but my two quantum boards are 120v. Does a controller exist that allows for 240v output receptacles as well as 120v output receptacles? I've pretty well accepted the fact that I will most likely have to install a 240v 4 light timer for the HID's and then a separate timer for my two LED boards. It would just be so nice to have them all on the same timer, however I don't see that as an option anywhere. Here are the two I'm looking at:
#1) Titan Controls® Helios® 4 - 4 Light 240 V Controller with Relay Trigger Cord
https://www.titancontrols.net/shop/product/titan-controls-helios-4-4-light-240v-controller-with-relay-trigger-cord_1?categoryId=lighting_3
This one has a 2 amp 120v receptacle on the front of the controller that I like. I can plug in an inline fan or even my 450w LED board. Then I would have 5 lights on the controller and only 1 light on a separate timer. I think this might be as good as I can do.
#2) MCL 8 Outlet HID hydroponic Master Light Controller Electric Box 120v /240v 50A
https://www.ebay.com/itm/MCL-8-Outlet-HID-hydroponic-Master-Light-Controller-Electric-Box-120v-240v-50A/401339313659?epid=1665035033&_trkparms=ispr=1&hash=item5d71afedfb:g:JZQAAOSwiB9dl-gJ&amdata=enc:AQAFAAACcBaobrjLl8XobRIiIML1V4Imu%2Fn%2BzU5L90Z278x5ickkTboA95HSvGa1O5UmCCGJLpKOAGzK2%2F7ZlpI3IW5rYHfzew7kyl3%2Bv825XsIh7WjXm94AD5iwpF%2BCaxslv2PIx40ijO1HVl%2BO3u8X87q23O7Ap3UmwFejbENda22VmM8PBVzFBEloCmuWD%2BoqNMpTCGMMpAtExxttMvY3PdzPVXK1AFWG%2FYWKwxFfWaet5lkNlD7BSti0%2BdLXukTPm8SD%2FfvpYcUcwSvwQub52Xv9NtM02WpoTMCkzyM3qlDlaG9D50f7Bx55pB0il8s6CVUU2xtpEdJCK2l05riGN8ui0KZGnAtNkghxlF%2FTLqSgxvy2QyyEH2J9niZ9VWPtu7VPk4ysr2%2Fb7Icwfg5MH3Ib0nunzZh%2Fw0DaPSp%2B5zCf4auOHIy9rMHEsVg%2FbazoSUu0OUlQ0lQkNLW7I476Z5Sfw087WgmfyWjXht57KcXboLhWSvgmc0Vq%2BQo30jjkpj84vNlZcLT2fTmemEUuW1JcOlD7YlOjM%2F3%2BCZoQkil3C75pEzgEzhnZBYAk%2BH5m3c7caVeJ2xisv2O%2FQj%2FSDoQ3jWmqCDT3Avtrwbem2HM0NNcw5A2eeYRPnk5rirELM9oyp7%2BFanDzJa%2BmJD1h05IiqYR%2FYsQvSkwUt7TD4kUC1%2Fb7fJYLXdgMUh6ZoKkweMF8DJlwkE9elrNvQXImBtWf8S29u65ar6YWSGnLfkMNsnwtEj5ocFQ%2F1s3d0wCq3R%2BPyklyR2PVTWfHQ1j63f6g1wMNQZezvxklAWcor61nmte2omqKEhVaeMfXBv98e7irFw%3D%3D|cksum:401339313659da6be4aa1b8046d2b596a821b882f133|ampid:PL_CLK|clp:2334524
I'm not an electrician so hopefully someone more savvy can help me decipher the capabilities of the unit above. It says:
#1) Titan Controls® Helios® 4 - 4 Light 240 V Controller with Relay Trigger Cord
https://www.titancontrols.net/shop/product/titan-controls-helios-4-4-light-240v-controller-with-relay-trigger-cord_1?categoryId=lighting_3
This one has a 2 amp 120v receptacle on the front of the controller that I like. I can plug in an inline fan or even my 450w LED board. Then I would have 5 lights on the controller and only 1 light on a separate timer. I think this might be as good as I can do.
#2) MCL 8 Outlet HID hydroponic Master Light Controller Electric Box 120v /240v 50A
https://www.ebay.com/itm/MCL-8-Outlet-HID-hydroponic-Master-Light-Controller-Electric-Box-120v-240v-50A/401339313659?epid=1665035033&_trkparms=ispr=1&hash=item5d71afedfb:g:JZQAAOSwiB9dl-gJ&amdata=enc:AQAFAAACcBaobrjLl8XobRIiIML1V4Imu%2Fn%2BzU5L90Z278x5ickkTboA95HSvGa1O5UmCCGJLpKOAGzK2%2F7ZlpI3IW5rYHfzew7kyl3%2Bv825XsIh7WjXm94AD5iwpF%2BCaxslv2PIx40ijO1HVl%2BO3u8X87q23O7Ap3UmwFejbENda22VmM8PBVzFBEloCmuWD%2BoqNMpTCGMMpAtExxttMvY3PdzPVXK1AFWG%2FYWKwxFfWaet5lkNlD7BSti0%2BdLXukTPm8SD%2FfvpYcUcwSvwQub52Xv9NtM02WpoTMCkzyM3qlDlaG9D50f7Bx55pB0il8s6CVUU2xtpEdJCK2l05riGN8ui0KZGnAtNkghxlF%2FTLqSgxvy2QyyEH2J9niZ9VWPtu7VPk4ysr2%2Fb7Icwfg5MH3Ib0nunzZh%2Fw0DaPSp%2B5zCf4auOHIy9rMHEsVg%2FbazoSUu0OUlQ0lQkNLW7I476Z5Sfw087WgmfyWjXht57KcXboLhWSvgmc0Vq%2BQo30jjkpj84vNlZcLT2fTmemEUuW1JcOlD7YlOjM%2F3%2BCZoQkil3C75pEzgEzhnZBYAk%2BH5m3c7caVeJ2xisv2O%2FQj%2FSDoQ3jWmqCDT3Avtrwbem2HM0NNcw5A2eeYRPnk5rirELM9oyp7%2BFanDzJa%2BmJD1h05IiqYR%2FYsQvSkwUt7TD4kUC1%2Fb7fJYLXdgMUh6ZoKkweMF8DJlwkE9elrNvQXImBtWf8S29u65ar6YWSGnLfkMNsnwtEj5ocFQ%2F1s3d0wCq3R%2BPyklyR2PVTWfHQ1j63f6g1wMNQZezvxklAWcor61nmte2omqKEhVaeMfXBv98e7irFw%3D%3D|cksum:401339313659da6be4aa1b8046d2b596a821b882f133|ampid:PL_CLK|clp:2334524
I'm not an electrician so hopefully someone more savvy can help me decipher the capabilities of the unit above. It says:
- This controller will run ( HID lights at 240 Volts or 120 Volts for 6 HID light - Maximum 8000
Watts. Each Outlet can handle 1000W. Keep in mind maximum amperage is 50amp for all 8 outlet. - Two Extra 120V Outlet