  1. abellguy

    This is how we do it on the other side (Was the $26,500 Thread)

    First off I would like to say a big I am sorry to Ben for f***ing your thread up again!! Your post, LoudBlunts, does nothing but say that because I am not on here all day, I do not have all my pictures of my achievments up, I do not have a journal abailable for all to look at (in other words I...
  2. abellguy

    This is how we do it on the other side (Was the $26,500 Thread)

    I am def not trying to bash anybody or cause a problem for anybody. All I am saying is that it seems from other peoples posts that Ben has done something wrong and LoundBlunts hasn't. I think if you read over all the posts about this you will see that isn't the case. And again I don't mean to be...
  3. abellguy

    This is how we do it on the other side (Was the $26,500 Thread)

    I am not sure how Ben did anything to make LoudBlunts react the way he did. I replied to Ben on page 15 (with the correct information on how to fix his problem) ONLY because he said if anyone with usable information could post he would like it. Cause like me he found 0 here that make any sense...
  4. abellguy

    This is how we do it on the other side (Was the $26,500 Thread)

    I am glad to hear all is working well now. I have no idea why HI is telling you to hook it up the way you had it. You should have no problem with running two tents on the one chiller. Once you get a little more run lenght the chiller might have to run a little more to keep it at your required...
  5. abellguy

    3600watt growroom setup w/ rotation. Need advice from experianced growers

    As far as electric goes most all ballasts have taps to be rewired for 240 even if there are 120 you just need to open it up and check it out with a multi-meter. If you are not experienced with this kind of thing best to have an electrician friend help you out or hire an electrician and ask a lot...
  6. abellguy

    3600watt growroom setup w/ rotation. Need advice from experianced growers

    What up SoCaler?! Welcome to the inside I have never been out so maybe we can help each other as my forte' is inside. For starters #'s, I believe its 6 mature plants OR 12 imature plants you are legally allowed to have. Whith the definition of the mature and imature I do not know where they...
  7. abellguy

    This is how we do it on the other side (Was the $26,500 Thread)

    Thank you very much for the update on how it all worked out. I am very sorry if some how I caused some kind of problem cause of the fact that I only have 20 posts, and am giving you way different ideas then what others are giving you as well as the manual you got with your equipment. (which by...
  8. abellguy

    6OOO watt ventillation question

    I would let co2 be your last thing you add. Get the room working 100% properly as far as air exchange which is #1 in indoor gardening and goes hand in hand with light intensity for #1 so both need to complement each other. A chiller for your setup will be about a grand but you can order it on...
  9. abellguy

    6OOO watt ventillation question

    Another good thing to keep in mind is that it is much better to have to throttle your room back to your desired temp. rather than have to have everything working all out just to get sort of close to where you want your temp. to be at. Not only for the equipment but just for how your environment...
  10. abellguy

    6OOO watt ventillation question

    The attachment by Erik states some good points on air cooling and exchange as well as how good water cooling is. You can achieve some of the same results with the ice box (for cheap air conditioning) and a good charcoal filter along with having any "in" covered by good filters. The bad part...
  11. abellguy

    6OOO watt ventillation question

    I would never post on any topic that I did not have direct involvment with or understand completley what is at hand when given questions regarding why I have posted about something. Why I did not give suggestions on the normal way you "air cool" a room, notice I didn't say "air condition" a...
  12. abellguy

    6OOO watt ventillation question

    6000 watts will put so much heat into any room no amount of air cooling alone will take care of it. As previous posters have mentioned you have to control the heat to have an effective grow with that much wattage. In my opion from banging my head against a wall, I found out that trying to run a...
  13. abellguy

    Is connecting the filter directly to the fan OK or better put some ducting inbetween?

    I am not sure about your specific filter but I am using a can 150 and from what I understand when it is filled with charcoal it is vibrated to ensure that all the charcoal packs together. You could check on the manufacturing process for your filter and see if it is the same. I have my can...
  14. abellguy

    This is how we do it on the other side (Was the $26,500 Thread)

    WOW 4 1HP chillers you are setup man. By doing what you are today you will stop your chillers from running hardly at all. If you remove your ducting from the exit side of the ice box you should have almost too cold of a room at that point. Wow you aren't F'in around at all with your setup...
  15. abellguy

    This is how we do it on the other side (Was the $26,500 Thread)

    If you only have one pump you cant have a cold res. you just have a res. of water that has hot water dumping into into it sort of staying in the top especially if you have a baffel system. then water being pumped to the chiller and to the lights. The two pump system would allow you to keep the...
  16. abellguy

    This is how we do it on the other side (Was the $26,500 Thread)

    I am not sure I see how they are different. One system is sending water through a "radiator" and one is sending water through the housing. In liquid lumens the water in the housing surrounds the bulb and transfers the heat away in the water. On ice box it puts cold water into a radiator and...
  17. abellguy

    This is how we do it on the other side (Was the $26,500 Thread)

    It is hard to get completly I think cause of wording. But it sounds like he has only one pump, unless his chiller is such that it holds the water inside of it cold and then pumps from there to the system as you see it as he says then it would work. Otherwise he needs two pumps one going from...
  18. abellguy

    This is how we do it on the other side (Was the $26,500 Thread)

    It sounds like he doesn't have the chiller on a closed loop system to the res.:joint:
  19. abellguy

    This is how we do it on the other side (Was the $26,500 Thread)

    It sounds like he is running his water line from the res. to the chiller then on to the light system, that would mean he is only getting the amount of cool water that the chiller will hold/pass by, and only cooled to the point that the chiller can do on a constant basis. No condesing type unit...
  20. abellguy

    This is how we do it on the other side (Was the $26,500 Thread)

    If I am understanding you right you are running the water from your res. on a 1500gph pump to the chiller and then to the lights. If you run the system with two pumps one running say 300-500gph to the chiller and back to the res. Then run another pump that in the end will be running slower gph...