Search results

  1. Zdeezy

    4'x4' one plant ScrOG? Perpetual every 2 weeks? help!

    Ive read alot of that and got alot of great info and the basics of what i need to do. I just want some input on if i should do 1.or 2 plants under each screen?
  2. Zdeezy

    adding air cooled hoods and CO2 have questions

    pull air from another room and then send it out the other side or out the chimney or window. or into the attic. Need more info on your room.
  3. Zdeezy

    4'x4' one plant ScrOG? Perpetual every 2 weeks? help!

    Alright so heres the scoop. right now I'm harvesting 4 plants every 2 weeks for a total of 16 plants in flower and 8 in veg. Im getting 4 oz per plant. I top them a week before flower and trim them about 1/3 of the way up 1 week into flower. (thinking about changing that into the 2nd week of...
  4. Zdeezy

    Humble Servant's 1000W One Plant Fully Organic Orange Crush SCROG Journal

    Nice setup! Im thinking of doing a 1good plant scrog just to get my #'s down. Im trying to figure out how if i can pull a lb off a plant with a scrog and a 2. Month veg. Currently i harvest 4 plants every 2 weeks giving me a lb. Thats onlu with a 4 week veg In 7 gal pots. Think it can be done?
  5. Zdeezy

    Help Cooling a basement grow!!!

    Yes dual hoses will still pull air out of your room. My whole front yard reeks whenever the AC comes on. But I will solve this problem by rerouting the exhaust to my 6"inline that turns on with the AC and then all the stinky stink will go out the chimney with all the other hot/stinky air. If you...
  6. Zdeezy

    Help Cooling a basement grow!!!

    Go with the mini split or the window shaker. Do you gave anywhere to vent on the outside of the room? You could always build a custom box around the AC to exhaust the heat out of your basement.
  7. Zdeezy

    AC Questions

    Use the window AC. They are more efficient and won't suck air out pf your room. I have a dual hose portable and it still sucks out the air in mu room so I had to buy a controller so I wasn't losing all my co2
  8. Zdeezy

    please help!! dual hose ac and co2!

    What size room are you in and how many watts are you running? I have the sentinel evc2 environmental controller. My 12k BTU runs for 20 mins then is off for 20 mins. My rooms 10'x15'x7' with 2 air cooled 1000's and 2 600w in open hoods.
  9. Zdeezy

    humidity jumping around

    Alright cool. Yeah as soon as the AC and exhaust kick on its right back to 35%. Thanks for.your input!
  10. Zdeezy

    humidity jumping around

    Alright so I am running a sealed room with 3200w, two 1000w in cooled hoods and 2 600w in open hood. Got a 12k BTU portable AC and 6"inline for exhaust. This is all hooked to my environmental controller. My 2 temps stay between 83.5° and 88.5°. When temps get down and AC and exhaust shut off the...
  11. Zdeezy

    3x600w vs 2x1000w?

    I'm trying to get people's opinions on what I should do with my situation. I am currently running 2x1000w in air cooled hoods and 2x600w in open 4'x4' hoods. My AC is running a little bit more than I like the but my room is staying between 83.5-88.5°. When the temp gets to 88.5 my controller...
  12. Zdeezy

    how do you run your clone-veg-flower cycle????

    Why are you just going to put them around the light? You should fill up the middle, that's where the best light is.
  13. Zdeezy

    how do you run your clone-veg-flower cycle????

    I'm also a Michigan medical patient. The way I have mine set up is to harvest 4 plants every 2 weeks. So for 1 week I will have 20 plants in flower and then the next week I will have 16 plants in flower. (All strains are 9 weeks. Blueberry skunk, white fire og, sour diesel and sour kush) I have...
  14. Zdeezy

    how long should a 20lb tank last in a 1300 scf room?

    I have a sentinel evc2 environmental controller with a cap ppm-4 co2 monitor. The room is completly sealed but my dual hose portable ac was sucking out my co2. thats why i had to get the environmental controller. it last about a week now. which is about right for the size room i have.
  15. Zdeezy

    exhaust noise too loud

    You could always Y your 2 6" into one 8" line. The Y your 2 4" lines into another 8" line and then Y the 2 8" lines into one single 10" line hooked up to a muffler out pf your window :). Just another idea for you to consider. It would he really easy too.
  16. Zdeezy

    Finding the right co2 controller : I know it's been asked a million times

    I got the cap ppm4 hooked up to my 20lb tank. It works good. It's plugged into my sentinel evc2 environmental controller. I like the set up.
  17. Zdeezy

    AC competing with the exhaust?

    My rooms almost the same size as yours. I'm running a closed co2 enriched environment and my temps were getting up to 95°. I bought a 12k BTU dual hose portable and the sentinel evc2 environmental controller. It turns my AC and exhaust fan on and shuts the co2 off. I would close up the intake...
  18. Zdeezy

    for alk you enviromental controller users

    You are correct about the nickel and dime part...it was 500$a for the AC and 300$ for the controller. I could of got a mini split for that price.
  19. Zdeezy

    for alk you enviromental controller users

    I just bought the sentential evc-2 controller and all my problems are solved. I set it to 83° with a 6°temperature dead band so it goes upon to 89.5° then kicks my co2 off and turns on the AC and 6"inline exhaust on the cieling. It takes 8-10 mins to cool it down to 82.5 then co2 comes back on...
Top