I dont understand?Also on the feed line coming off of the pump has 2 12 lines coming off that connect to multiple other lines that creates a u shape . Can't I just remove that u shaped hose and connect straight to my buckets?
Also on the return lines being completely on the floor I have my reservoir outside of the tent and the hoses ran through the very bottom of the tent . There is a pole at the bottom of the tent so the return lines have 2 elevate a tiny bit to get over the pole . Any suggestions how to keep them flat ?I will fix that as well because some of the return lines are not completely flat thank you
2x4 with a weight onit,a little up is ok as long as all 4 are the same.Also on the return lines being completely on the floor I have my reservoir outside of the tent and the hoses ran through the very bottom of the tent . There is a pole at the bottom of the tent so the return lines have 2 elevate a tiny bit to get over the pole . Any suggestions how to keep them flat ?
or go under the pole but those hoses are soft arn't they?Again smack the dude that built this.2x4 with a weight onit,a little up is ok as long as all 4 are the same.
Ok so the submersible pump has a 12 in hose connected to it . Which connects to a single plastic connector which connects to another 12 inch hose and then that hose connects to a t shaped connector which has 2 12 inch hoses coming off of that on each side, and then finally each of those hoses are connected to another single connect which connects to 2 12 inch hoses which connects tobthe buckets. Couldn't I just remove the last 2 12 in hoses and connect straight to the buckets?I dont understand?
The T connector is the beginning of the manifold it has to stay.water goes around in a circle creating equal pressure at ea site.
Like i said use the same fitting that at the closest pails on the end pails to join them together easy fix.
I planned on keeping the T connect I was just wondering if the last 12 inch hoses were necessaryThe T connector is the beginning of the manifold it has to stay.water goes around in a circle creating equal pressure at ea site.
Like i said use the same fitting that at the closest pails on the end pails to join them together easy fix.
I wasn't planning on removing the T connect my question is are the 2 last 12 inch hoses necessary? Or could I just remove them and hook straight to my buckets?The T connector is the beginning of the manifold it has to stay.water goes around in a circle creating equal pressure at ea site.
Like i said use the same fitting that at the closest pails on the end pails to join them together easy fix.
No they are not real softor go under the pole but those hoses are soft arn't they?Again smack the dude that built this.
I could definitely remove all of the feed lines and start over and would love expert opinions on how to do it properlySo if your able i would remove all the feed hoses and start over.You cant move your pails around because of how its designed.let me know what you can get and if your able to do it.
2 of my buckets have t connects on top and 2 have just a single connect. Should they all 4 be connected?I could definitely remove all of the feed lines and start over and would love expert opinions on how to do it properly
Here a red line shows what needs to be done to complete the manifold. This is the easy fix. But u can’t move your buckets around there stuck at that distance apart2 of my buckets have t connects on top and 2 have just a single connect. Should they all 4 be connected?
Makes sense thank you . You had mentioned a valve to control water how do i get those or where do I put them ?A Tee at ea pail. Hose goes between.so two Tees and what ever length hose. This makes a circle of the flow. So now each hole or pail will have equal pressure.
No need for valve there if connect the two together.Makes sense thank you . You had mentioned a valve to control water how do i get those or where do I put them ?
Yes you need a Tee a couple of short hoses and a valve for in your res.Makes sense thank you . You had mentioned a valve to control water how do i get those or where do I put them ?
One more question I read the hoses at the bottom are not big enough because they will get clogged with roots . How do I fix that ?So ideally you have a short Manifold in your rez. Then 4 hoses coming out one to ea site. This allows them to run on the floor out of the way then up to ea site. You can now move your pails apart from ea other as your plants grow. This also has no fittings out side of your res so no chance of leaks.
there’s other ways but no fittings outside of your res is the best. No chance of leaks.