Where can you purchase Vero 29 (version 2) 4000K Bins?

str8quad5

Member
Hi there folks! I'm trying to find somewhere to purchase Vero 29 V2 4000K Bin's in the USA or Preferably Canada to avoid shipping across borders or paying currency exchange on USD. Anything in AU Dollars works too! Thanks in advance!
 
Last edited:

Danielson999

Well-Known Member
http://www.digikey.com/catalog/en/partgroup/vero-29-array-series/43475

This is OLD
BXRC-40E10K0-L-03
BXRC-40G10K0-L-03

This is new V2 but is 90 CRI so less efficient
BXRC-40G10K0-L-23

This is NEW V2 4000k 80 CRI that you want
BXRC-40E10K0-L-23
Hey Robin, in a small closet tent (2x4) do you think the difference in heat produced running 3 Vero's @80w and 4 Vero's at 54w will be a factor worth considering or simply negligible? It would actually end up being 6 Vero's@80w or 8 Vero's@54w in that tent. Thanks.
 

robincnn

Well-Known Member
@Danielson999
2x4 = 8sqft
6x 80 watts gives 480 watts
8x54 watts gives 432 watts
I would be more concerned with the heat from this extra 50 watts and not so much with the extra heat due to efficiency. Depends on your setup so can't help much. You can always dim them if too much heat.
I used two 80 watts in 2x2 Ta 68F
Lights on temps around 78F. So heat was no issue. I had to add extra heatmats in winter.
Summer temps should be fine too

Both these configs are over 50 watt per sqft.
Dawg used invertronics that powers 80x4 veros
320watts/8 = 40 watts/sqft is also good.
https://www.rollitup.org/t/the-dawg-fathers-diy-vero29-960-watt-5x5-scrogg.897056/
 
Last edited:

STR8QU4D5

Active Member
@Danielson999
2x4 = 8sqft
6x 80 watts gives 480 watts
8x54 watts gives 432 watts
I would be more concerned with the heat from this extra 50 watts and not so much with the extra heat due to efficiency. Depends on your setup so can't help much. You can always dim them if too much heat.
I used two 80 watts in 2x2 Ta 68F
Lights on temps around 78F. So heat was no issue. I had to add extra heatmats in winter.
Summer temps should be fine too

Both these configs are over 50 watt per sqft.
Dawg used invertronics that powers 80x4 veros
320watts/8 = 40 watts/sqft is also good.
https://www.rollitup.org/t/the-dawg-fathers-diy-vero29-960-watt-5x5-scrogg.897056/
Hey Robin, what would you suggest I do if I want to increase yield over efficiency using the Vero29 V2 in regards to the CRI's?
 

robincnn

Well-Known Member
Hey Robin, what would you suggest I do if I want to increase yield over efficiency using the Vero29 V2 in regards to the CRI's?
Efficiency impacts total light output. Total light output impacts yield. Spectrum is important too.
You are asking if 90cri has better spectrum.
I have not seen the SPD for 90cri vero 29. Nor do I know LER for 90 CRI version or the complex math. Only a few(not me) can do the math if any if any info were available.

Given limited info I would put money on 80 CRI as high CRI are usually less efficient.

You get 14% more lumens with 80 CRI 4000k 137lm/w compared with 90 CRI 4000k 118lm/w

Read this thread for a better idea
https://www.rollitup.org/t/cxa-3000k-80-vs-93-cri-an-estimation.833171/

And then read this post by alesh
https://www.rollitup.org/t/co2-fixation-calculation-tool-for-cobs.896232/#post-12241662
 

STR8QU4D5

Active Member
Efficiency impacts total light output. Total light output impacts yield. Spectrum is important too.
You are asking if 90cri has better spectrum.
I have not seen the SPD for 90cri vero 29. Nor do I know LER for 90 CRI version or the complex math. Only a few(not me) can do the math if any if any info were available.

Given limited info I would put money on 80 CRI as high CRI are usually less efficient.

You get 14% more lumens with 80 CRI 4000k 137lm/w compared with 90 CRI 4000k 118lm/w

Read this thread for a better idea
https://www.rollitup.org/t/cxa-3000k-80-vs-93-cri-an-estimation.833171/

And then read this post by alesh
https://www.rollitup.org/t/co2-fixation-calculation-tool-for-cobs.896232/#post-12241662
Ok thank you!
 

str8quad5

Member
Correct only 1
Driver 31V ~ 62V , Vero needs 39-40V for this current
with 1750 it can run 2 Veros
note that this driver is 180-305VAC. It will not work on USA 120VAC
Robin, what would you recommend for a driver on Mouser (thats in stock right now, I need EIGHT that I can run 4 Vero 29's V2 4000K CRI 80's at 200W? Also, I will be running 4 CPU coolers with fans on them, so I'll need power for that too. Suggestions?
 

djsence

Member
Correct only 1
Driver 31V ~ 62V , Vero needs 39-40V for this current
with 1750 it can run 2 Veros
note that this driver is 180-305VAC. It will not work on USA 120VAC

Hello there Robin,

I have been lurking for a long time, Iv'e made a few DIY LEDs with the cheap dodgy ones on Ebay. I just recently received my LEDs and other parts. I have a question for you ( I know everyone does) but you seem to be the most knowledgeable on the Vero set-ups.

I have 4 Vero 29s powered by a HLG-120H-C1050B. The heatsink is from heatsink us and is 5.886" and 27" long.

My question is : Will I need to mount a 12v fan to cool this or do you think it will be able to run passively?

I will be ordering another 4 Vero Leds soon, is there a better driver I should be looking at?

Thanks in advance!

\



Also i don't mean to thread jack, I didn't see the need to open another thread on this,,,,
 

robincnn

Well-Known Member
Robin, what would you recommend for a driver on Mouser (thats in stock right now, I need EIGHT that I can run 4 Vero 29's V2 4000K CRI 80's at 200W? Also, I will be running 4 CPU coolers with fans on them, so I'll need power for that too. Suggestions?
Use http://www.findchips.com Search for HLG-240H-C1400.
Mouser has 3 in stock. HLG-240H-C1400 would be a over 200 watts. around 220
For fans i use APV-12-12. it is 1amp supply. Any 12 V power supply should do fine. Add up current on all 4 fans and make sure it is less than or equal to rated current of 12V driver.

Hello there Robin,
I have been lurking for a long time, Iv'e made a few DIY LEDs with the cheap dodgy ones on Ebay. I just recently received my LEDs and other parts. I have a question for you ( I know everyone does) but you seem to be the most knowledgeable on the Vero set-ups.
I have 4 Vero 29s powered by a HLG-120H-C1050B. The heatsink is from heatsink us and is 5.886" and 27" long.
My question is : Will I need to mount a 12v fan to cool this or do you think it will be able to run passively?
I will be ordering another 4 Vero Leds soon, is there a better driver I should be looking at?
Thanks in advance!
Also i don't mean to thread jack, I didn't see the need to open another thread on this,,,,
https://www.rollitup.org/t/heatsinks-for-diy-led-lamps.851907/
260*27/144=48 so good for 50 to 60 watt passive. but you are near 150 watts
You will need a fan. I would add a 120mm or 140mm fan
If you want to run at 1050ma with 4 vero 29 then you have a good driver already. You can consider HLG-240H-C1400 or HLG-240H-C2100 if you want to drive your veros harder.
 

djsence

Member
Use http://www.findchips.com Search for HLG-240H-C1400.
Mouser has 3 in stock. HLG-240H-C1400 would be a over 200 watts. around 220
For fans i use APV-12-12. it is 1amp supply. Any 12 V power supply should do fine. Add up current on all 4 fans and make sure it is less than or equal to rated current of 12V driver.


https://www.rollitup.org/t/heatsinks-for-diy-led-lamps.851907/
260*27/144=48 so good for 50 to 60 watt passive. but you are near 150 watts
You will need a fan. I would add a 120mm or 140mm fan
If you want to run at 1050ma with 4 vero 29 then you have a good driver already. You can consider HLG-240H-C1400 or HLG-240H-C2100 if you want to drive your veros harder.

Thanks for the reply. Great info there on heat sinking for sure, I will check out those two drivers today. I need to get my second build ready to roll. I would assume both of those drivers are available in B series for dimming. That's one thing I am shooting for on all my builds. Cheers!
 

Danielson999

Well-Known Member
@robincnn

What would the numbers look like in a 2x4 tent with 12 or 15 Vero 29's running at 700ma. For simplicity sake I was thinking about 2 fixtures with 6 cobs in each running off an HLG-120H-C700 each.
6 cobs x 24.9w = 149.4watts per 4 sqft = 37.35watts per sqft.

Could you help me figure out the efficiency and PPFD for this setup? I'd like to base it off the 2 fixtures with 6 cobs in each but I might consider adding a strip of 3 more just to boost the numbers if need be. growlight.jpg
 

robincnn

Well-Known Member
@robincnn

What would the numbers look like in a 2x4 tent with 12 or 15 Vero 29's running at 700ma. For simplicity sake I was thinking about 2 fixtures with 6 cobs in each running off an HLG-120H-C700 each.
6 cobs x 24.9w = 149.4watts per 4 sqft = 37.35watts per sqft.

Could you help me figure out the efficiency and PPFD for this setup? I'd like to base it off the 2 fixtures with 6 cobs in each but I might consider adding a strip of 3 more just to boost the numbers if need be. View attachment 3603752
Use this sheet and the attached calculator. Good luck.

Spreadsheet by Supra and calculator by CanadianOne

http://ledbuilder.org/index.php?forums/project-plans-how-to-guides.9/
 

Attachments

Top