Badbillybuds
Member
This is priceless to me. I can't thank you enough.
Thinking that's the best. What Renbro says goes. Plus add 6 scrubbers could be the way. Have a meeting later this week and will see what it entails to get sorted, Currently have the 3phase being sorted.Nice, hey I was going to say what was mentioned above and just run a sealed room with proper A/C. It would probably save you a lot of headaches.
A/C in a SEALED room where you exhaust inky during lights off when plants don't need co2, you'd wanna use mini splits. Not actual AC units.Thinking that's the best. What Renbro says goes. Plus add 6 scrubbers could be the way. Have a meeting later this week and will see what it entails to get sorted, Currently have the 3phase being sorted.
I added a 2 ton mini split to my grow room and sealed it(not even close to the size yours is going to be) and it was the best decision I've made. That's the best part is you can just have inline fans and carbon filter blowing air around inside room. Dehus are a must though.Thinking that's the best. What Renbro says goes. Plus add 6 scrubbers could be the way. Have a meeting later this week and will see what it entails to get sorted, Currently have the 3phase being sorted.
When I was in Australia we were using airconditioners. I don't think we even had fresh air pumping in. Everything grew well even through 40c summers. As Renfro said, couple of 16inch intakes and will add sever carbon filters. Smell has to be controlled. At have the electrician in doing the wiring, all 3 phase. For the strain I'm thinking of mostly Bruce Banner. I have an excellent pheno , even in SOG i have got 3oz from one. plant. which is good imho. Plus not alot of trimming, not so susceptible to mold. For this crop I'm going to make 2* 1000l tanks of nutrients. Would prefer GH, but need to import, so the option's are Canna, House n Garden, Emerald harvest, Perhaps Green Plant, but need to import from Australia. Also, for this one crop I will hand water with wand from the tanks and run to waste. Any suggestion's on Nuts are welcome. Thanks for all the replies also, appreciated.I added a 2 ton mini split to my grow room and sealed it(not even close to the size yours is going to be) and it was the best decision I've made. That's the best part is you can just have inline fans and carbon filter blowing air around inside room. Dehus are a must though.
Do you “exhaust” the heat produced by the dehumidifier into a lung room? I guess I’ve never found a clear answer about that aspect of a sealed room. In a truly sealed room I assume that the heat produces by the dehumidifier just gets handled by the mini split? I’m struggling with this as I’m building out my space and deciding where to place everything. Love your thread, I still have so much to catch up on! Thanks for sharing with us allRight now I have my flowering rooms running with AC and CO2, dehu. But I sometimes just turn off the dehu if the air is dry outside and temps are workable, then if the RH% hits 50 the room vents down to 40% and then the CO2 generator kicks back on... So I am using the intake blower as a dehumidifier. Lest nite, this AM the ambient RH% was too high so I disabled the venting and turned the dehumidifier on until the #'s went down this afternoon.
The AC unit picks up any heat loads from dehumidifiers, CO2 generators... Exhausting would cause air to come in to replace it, that would negate the dehumidification if the ambient RH% is higher than your target.Do you “exhaust” the heat produced by the dehumidifier into a lung room?
They are good, just got done chopping Room B yesterday. Looks like 24 - 26 pounds, will know more when it's dried and trimmed. That mimosa makes big, dense logs. Heavy plant.how are the girls doin?
I’m moving out of tents and into a sealed room but building it around an active grow. It’s all been speculation thus far so getting these answers is gold. You definitely saved me from cutting unneeded holes in soon to be built walls. Thank you!The AC unit picks up any heat loads from dehumidifiers, CO2 generators... Exhausting would cause air to come in to replace it, that would negate the dehumidification if the ambient RH% is higher than your target.
I ran my flood and drain on tap water for years no issue, I’m sure you’ll be fine.I stuck some clones in the tent because I had extras and I was bored. I figured I would see how they do without the RO water running flood and drain. So far so good about a week into flower. I will do my best to run the reservoir without change outs. The only issue I have is the need to add a few mL of pH down to the reservoir each day as the pH rises a few points each dark cycle when the timed float valve tops off the res. No calmag just epsom and GH trio.
Ya luckily my internet is pretty good, doesn't go out much, occasionally won't work when I'm on phone but very rare., next thing I need to get is a back up generator since I have a generator side port that can power some of my electrical box circuits, thus powering my grow room if need be.About the only negative thing I have heard about them is that if the internet goes out it gets stuck in the mode the AC was set to when the internet went out.